Aim: This study aimed to evaluate the fracture resistance of implant-supported fixed partial prostheses fabricated from monolithic zirconia with different pontic framework designs and anchored in different bone-like simulation models of two different densities.

Materials And Methods: A total of 60 implants were anchored in two different bone simulation models of two different densities, namely, solid polyurethane foam blocks, 20 and 10 pounds per cubic foot (PCF) to construct implant-supported fixed partial dentures (FPDs), the pontic constructed to replace missing second premolar and first molar. Thirty models were constructed and then divided into two groups according to anchoring material D2 ( = 15) and D3 ( = 15). Each group of models was subdivided into three groups according to pontic design ( = 5). Each model was tested against fracture in a universal testing machine. The data were analyzed with a two-way univariate ANOVA and Tukey HSD test (α = 0.05). The results were statistically analyzed, and the values were considered significant at ≤0.05.

Results: The findings showed that neither change in pontic design nor change in bone type has a significant influence on the fracture resistance of the prostheses ( > 0.05). All the tested materials fell within the acceptable range for functioning under mastication, with a slight change in resistance when the pontic design was changed.

Conclusion: Zirconia is considered the material of choice when planning implant-supported FPDs because of its high fracture strength values. Within the limitations of this study, the pontic design and synthetic polyurethane bone-simulating model had no effect on the fracture resistance of four-unit implant-supported FPDs.

Clinical Significance: This study postulated that any pontic design could be used in four units of implant-supported FPDs according to functional and aesthetic needs, as long as the histological nature of the alveolar bone falls within the D2 or D3 bone type. How to cite this article: Othman MS, Abu-Eittah MRH. The Influence of Different Pontic Designs on Fracture Resistance of Implant-supported Fixed Partial Dentures Anchored in Polyurethane Simulating Bone-blocks of Two Different Densities: An Study. J Contemp Dent Pract 2024;25(7):684-690.

Download full-text PDF

Source
http://dx.doi.org/10.5005/jp-journals-10024-3721DOI Listing

Publication Analysis

Top Keywords

fracture resistance
20
pontic design
20
implant-supported fixed
16
fixed partial
16
resistance implant-supported
12
partial dentures
12
influence pontic
8
pontic designs
8
designs fracture
8
dentures anchored
8

Similar Publications

Background: The aim of this study was to compare the mechanical properties of the polymer brackets with metal and ceramic brackets and verify if the polymer brackets could be used clinically.

Materials And Methods: A thorough search was conducted in four electronic databases, including Scopus, PubMed, Cochrane, Ovid, and Lilacs, with article selection based on Preferred Reporting Items for Systematic Reviews and Meta-Analysis standards. A computerized search of the database was done from January 1990 to June 2024.

View Article and Find Full Text PDF

Bloodstream Infection Combined with Thoracic Infection Caused by : A Case Report and Review of the Literature.

Infect Drug Resist

December 2024

Department of Laboratory Medicine, Shanghai East Hospital, School of Life Sciences and Technology, Tongji University, Shanghai, People's Republic of China.

Objective: is usually found in urogenital tract infections and is associated with several extra-genitourinary infections, including septic arthritis, bacteremia, and meningitis. Here, we report a rare case of induced bloodstream infection with thoracic inflammation in a surgical patient.

Methods: A 56-year-old male who underwent surgery for multiple pelvic and rib fractures developed fever, pleural effusion, and wound exudation despite receiving prophylactic anti-infection treatment with cefotiam.

View Article and Find Full Text PDF

Fatigue cracking of rib-to-deck conventional single-sided welded joints is a prevalent issue in orthotropic steel decks (OSDs), significantly impacting their structural integrity and durability. Rib-to-deck innovative double-sided welded joints have the potential to enhance the fatigue resistance of OSD. However, Welding Residual Stresses (WRS) significantly influence the fatigue life of these joints, mandating its consideration in fatigue assessments.

View Article and Find Full Text PDF

Effect of cavity designs on instrumentation, obturation and fracture resistance of mandibular first premolars with Vertucci V canal.

J Endod

December 2024

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, 237# Luoyu Road, Wuhan 430079, People's Republic of China. Electronic address:

Introduction: This study aimed to assess the effect of cavity designs on instrumentation, obturation and fracture resistance for mandibular first premolars with Vertucci V canal.

Methods: Mandibular first premolars with Vertucci V canal were scanned with micro-CT. 20 teeth with moderately curved canal were prepared with conservative endodontic cavity (CEC/M) or traditional endodontic cavity (TEC/M), and 30 with severely curved canal were prepared with CEC (CEC/S), modified CEC (MCEC/S) or TEC (TEC/S).

View Article and Find Full Text PDF

Objectives: To compare the mechanical performance of partially replaced (repaired) intra-coronal restorations to totally replaced ones in root canal-treated teeth.

Methods: Thirty maxillary second premolars were selected according to strict criteria, mounted on moulds, and had mesio-occluso-distal (MOD) cavities prepared. Resin composite restorative material was used to perform the initial restoration, followed by aging procedures using thermo-mechanical cycling fatigue to replicate six months of intraoral aging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!