Rationale: Acalvaria is an exceptionally rare congenital disorder marked by the absence of flat bones of the cranial vault, dura mater, and associated muscles, while the facial bones and base of the skull remain intact. Typically, the central nervous system is unaffected. Due to their extreme rarity, reported cases in the literature are infrequent. This condition often results in fatalities, as newborns with this anomaly generally have short life expectancies. However, there are a few documented cases of prolonged survival.

Patient Concerns: A 1-day-old full-term Palestinian male born to first-cousin parents at 37 + 6 weeks gestational age presented with an excessively soft skull without scalp abnormalities. The mother experienced polyhydramnios during the last 7 weeks of pregnancy.

Diagnoses: Head ultrasound and X-rays confirmed the absence of skull vault bones and clavicles with normal facial bones. A CT scan showed well-formed brain structures and foci of hemorrhage in the left frontal lobe.

Interventions: Supportive care was the primary management approach. The patient received comprehensive care in the neonatal intensive care unit, with a focus on stabilization and monitoring.

Outcome: After 3 weeks in the neonatal intensive care unit, the patient showed normal feeding and function, but the prognosis remained poor. The patient's family was informed about the poor prognosis.

Lessons: This case reveals a unique combination of acalvaria and absent clavicles. Early antenatal diagnosis is essential but was delayed here. More research is needed to understand and improve the diagnosis of these conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556999PMC
http://dx.doi.org/10.1097/MD.0000000000040399DOI Listing

Publication Analysis

Top Keywords

facial bones
8
neonatal intensive
8
intensive care
8
care unit
8
novel presentation
4
presentation acalvaria
4
acalvaria clavicular
4
clavicular absence
4
absence case
4
case report
4

Similar Publications

Objectives: To assess the effect of patient positioning and general anesthesia on the condylar position in orthognathic surgery.

Materials And Methods: This prospective study included patients undergoing orthognathic surgery between 2019 and 2020. Four weeks prior to surgery (T0) cone-beam computed tomography (CBCT) scans and intra-oral scans (IOS) were acquired in an upright position.

View Article and Find Full Text PDF

Objective: To compare the closed reduction approach with open reduction (transparotid approach) in the management of condylar fractures for parameters such as postoperative facial nerve injury, trismus, and malocclusion.

Study Design: An analytical comparative study. Place and Duration of the Study: Department of Oral and Maxillofacial Surgery, The Armed Forces Institute of Dentistry, Rawalpindi, Pakistan, from 10th January 2022 to 1st October 2023.

View Article and Find Full Text PDF

Background: This study assessed stress distributions in simulated mandibular molars filled with various materials after the removal of fractured instruments from the apical thirds of the root canals.

Methods: Finite element models of the mesial and distal root canals were created, where fractured instruments were assumed to be removed using a staging platform established with a modified Gates-Glidden bur (Woodpecker, Guangxi, P.R.

View Article and Find Full Text PDF

Background: In dentistry, local anesthetic is frequently used to manage pain throughout several phases of dental treatments, including tooth extraction. The study aimed to compare the effectiveness of two techniques for controlling pain during mandibular exodontia (tooth extraction), specifically focusing on the pain experienced during injection and extraction of mandibular anterior and premolars teeth. The two techniques being compared are the intraligamentary injection technique (ILI) and the incisive nerve block technique (INB).

View Article and Find Full Text PDF

Background: The continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.

Methods: A complete denture was constructed over a mandibular edentulous epoxy model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!