A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of dural puncture epidural technique combined with programmed intermittent epidural bolus on labor analgesia: A randomized, double-blind, parallel-group, controlled clinical trial. | LitMetric

Background: Labor analgesia can be achieved by different approaches. The efficacy and safety of combined dural puncture epidural (DPE) with program intermittent epidural bolus (PIEB) are not well characterized. This study aimed to compare the efficacy and safety of DPE combined with PIEB vs epidural (EP) combined with PIEB for labor analgesia.

Methods: We performed a prospective, randomized, double-blind, parallel-group, controlled clinical trial. Eligible pregnant nulliparous women received either DPE combined with PIEB (group D) or epidural combined with PIEB (group E) for labor analgesia. Analgesia was initiated with 0.1% ropivacaine + 0.3 µg/mL sufentanil and maintained with PIEB at 12 mL/h. Primary outcome was the proportion of women with adequate analgesia within 10 minutes after the initiation of analgesics. Secondary outcomes (time to achieve analgesia, time to first request for additional analgesic, proportion of women required additional analgesic or epidural catheter adjustment and resetting, total labor duration, total analgesic consumption, level of anesthesia, and motor block), side effects, and patient satisfaction were also documented.

Results: Out of 174 enrolled women, 160 were included in the analysis. Baseline characteristics were comparable. The proportion of women who achieved adequate analgesia in group D was significantly greater than that in group E (38.8% vs 20.0%, P < .05). Compared with group E, group D also showed advantages in faster adequate analgesic achievement, more likely to reach adequate analgesia, a longer time to maintain analgesia, lesser requirements for additional analgesic, and better sensory blocks. There were no significant inter-group differences in other outcome measures.

Conclusions: Compared with epidural and PIEB mode, DPE and PIEB mode achieved better analgesia without increasing maternal or neonatal side-effects during labor.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556960PMC
http://dx.doi.org/10.1097/MD.0000000000040327DOI Listing

Publication Analysis

Top Keywords

combined pieb
16
labor analgesia
12
proportion women
12
dural puncture
8
puncture epidural
8
intermittent epidural
8
epidural bolus
8
randomized double-blind
8
double-blind parallel-group
8
parallel-group controlled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!