A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Broken spinal needle: Clinical case and a brief review of the literature]. | LitMetric

[Broken spinal needle: Clinical case and a brief review of the literature].

Rev Med Inst Mex Seguro Soc

Instituto Mexicano del Seguro Social, Hospital General de Zona No. 3, Servicio de Anestesiología. San Juan del Río, Querétaro, México.

Published: May 2024

Background: Spinal anesthesia can present various complications, one of which is the breakage of a spinal needle within the intrathecal space, which is one of the least frequent complications and it may be serious. A case of spinal needle breakage is presented, pointing out its risk factors and recommendations to reduce it.

Clinical Case: 5-year-old female patient, who was scheduled for removal of translocated intrauterine device causing chronic pain. When attempting a spinal anesthesia, stylet was removed from the needle and directed into the subarachnoid space. Upon extraction, the spinal needle was deformed and shortened. Immediately and with fluoroscopy and local anesthesia, the broken fragment was extracted without complications. Regional anesthesia is widely used in pregnant women, as it is considered safe. However, there are factors that increase the probability of a spinal needle breakage (obesity, pregnancy, emergency procedures, incorrect handling of the spinal needle, etc.). Even so, there are various recommendations (use of ultrasound, proper handling of the needle, reducing the number of attempts, etc.) that can reduce the risk of spinal needle breakage.

Conclusion: Risk factors for spinal needle breakage should be identified, in order to decrease its incidence.

Download full-text PDF

Source
http://dx.doi.org/10.5281/zenodo.10999015DOI Listing

Publication Analysis

Top Keywords

spinal needle
32
needle breakage
12
needle
10
spinal
9
spinal anesthesia
8
risk factors
8
[broken spinal
4
needle clinical
4
clinical case
4
case review
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!