A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The diagnostic accuracy of HE4 in the differential diagnosis of pleural effusions. | LitMetric

The diagnostic accuracy of HE4 in the differential diagnosis of pleural effusions.

Clin Chim Acta

Tissue Repair and Regeneration Laboratory (TR2Lab), Institut de Recerca i Innovació en Ciències de la Vida i de la Salut a la Catalunya Central (IrisCC), Ctra. de Roda, 70 08500 Vic, Barcelona, Spain; Faculty of Medicine, University of Vic - Central University of Catalonia, 08500 Vic, Barcelona, Spain; Department of Pathology Althaia Xarxa Assistencial Universitària Manresa, Spain.

Published: January 2025

Background: Pleural effusions are challenging to diagnose, with approximately 20-50% of malignant effusions not diagnosed by cytology. Human epididymal protein 4 (HE4) may be useful in the differential diagnosis of pleural effusions. In serum, this biomarker shows false-positive results in some benign diseases. The aim of this study was to evaluate the diagnostic utility of HE4 in this setting and to identify false positives.

Methods: Concentrations of HE4, adenosine deaminase, % polynuclear cells, and C-reactive protein, were determined in 238 pleural fluid samples and the estimated glomerular filtration rate (eGFr) in serum.

Results: HE4 values ​​differed significantly (p < 0.01) between malignant [median (IQR)] [1065 (2085)] pmol/L and benign effusions [699 (589)] pmol/L. HE4 concentrations in gynecological and pulmonary tumors were significantly higher than in other tumors. For a cut-off point of 3050 pmol/L, 22 % sensitivity and 100 % specificity were obtained. In patients with benign disease, significant increases in HE4 were identified only in those with eGFr < 30 mL/min/1.73 m [1050(596)] pmol/L, and not in those with eGFr > 30 mL/min/1.73 m [597(532)] pmol/L). Two cut-offs were established for maximum specificity, depending on the eGFr: 3050 pmol/L for eGFr < 30 mL/min/1.73 m and 1992 pmol/L for eGFr > 30 mL/min/1.73 m. A sensitivity of 28.5 % was obtained for patients with eGFr > 30 mL/min/1.73 m and 36.3 % for patients with eGFr < 30 mL/min/1.73 m. The sensitivity using a specific cut-off point was 29.7 %.

Conclusions: The determination of HE4 in pleural fluids demonstrates high specificity and low sensitivity. The use of specific cutoff points that are clinically adjusted improves sensitivity while maintaining maximum specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2024.120027DOI Listing

Publication Analysis

Top Keywords

pleural effusions
12
he4 differential
8
differential diagnosis
8
diagnosis pleural
8
he4
5
diagnostic accuracy
4
accuracy he4
4
pleural
4
effusions
4
effusions background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!