Objective: Stroke is a leading cause of disability and mortality worldwide, posing a significant public health challenge. While treatment of acute ischemic stroke (AIS) with recombinant tissue plasminogen activator (rt-PA) is effective but increases the risk of hemorrhagic transformation (HT). This study aimed to explore the determinants of HT in AIS patients treated with rt-PA and investigate the association between blood glucose levels and HT risk.

Methods: We conducted a prospective cohort study at the First Affiliated Hospital of Harbin Medical University from January 2018 to December 2021. Patients with AIS and who received rt-PA within 4.5 hours of symptom onset were included. Demographic, clinical, laboratory, and imaging data were collected.

Results: Of the 426 patients, 15% experienced HT post-rt-PA, occurred more frequently in patients with a history of cardiac embolism, higher prethrombolysis NIHSS scores, and elevated fasting blood glucose (FBG) levels. The frequency of HT was higher in non-diabetic patients with FBG levels ≥7.0 mmol/L compared to diabetic patients. Elevated blood glucose levels were significantly associated with HT, regardless of diabetes history.

Conclusion: The findings suggest importance of precise glycemic control during AIS management to improve patient outcomes, particularly in non-diabetic patients. Future protocols for AIS treatment should incorporate these findings to reduce HT risks. Further large-scale studies are needed to confirm these associations and guide clinical practices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11550918PMC
http://dx.doi.org/10.2147/CIA.S482060DOI Listing

Publication Analysis

Top Keywords

blood glucose
16
glucose levels
12
hemorrhagic transformation
8
acute ischemic
8
ischemic stroke
8
fbg levels
8
non-diabetic patients
8
patients
7
levels
5
ais
5

Similar Publications

Objective: To evaluate the therapeutic effects of Kuanxiong Aerosol (KXA) on ischemic stroke with reperfusion and elucidate the underlying pharmacological mechanisms.

Methods: In vivo pharmacological effects on ischemic stroke with reperfusion was evaluated using the transient middle cerebral artery occlusion (t-MCAO) mice model. To evaluate short-term outcome, 30 mice were randomly divided into vehicle group (n=15) and KXA group (n=15).

View Article and Find Full Text PDF

Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients.

Langenbecks Arch Surg

January 2025

Department of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.

Purpose: Pancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.

Methods: Thirty non-diabetic pancreatectomy patients participated.

View Article and Find Full Text PDF

Background: There is a lack of data on the validation and diagnostic performance of the Freestyle Optium Neo-H (Freestyle) and Centrivet GK (Centrivet) devices for the diagnosis of hypoglycaemia, hyperglycaemia and hyperketonaemia in goats.

Objectives: The aim of the present study was to validate the Freestyle and Centrivet for the analysis of whole blood beta-hydroxybutyric acid (BHBA) and to validate the Freestyle for the analysis of whole blood glucose concentrations using the reference method (RM) in goat blood collected from the jugular and ear veins.

Methods: Venous blood samples were utilised to assess glucose and BHBA concentrations using the Freestyle, Centrivet and RM.

View Article and Find Full Text PDF

A Hierarchical Core-Shell Structure of NiO@CuO-CF for Effective Non-Enzymatic Electrochemical Glucose Detection.

Nanomaterials (Basel)

December 2024

Guangdong Provincial Key Laboratory of Electronic Functional Materials and Devices, Huizhou University, Huizhou 516001, China.

Non-enzymatic glucose detection is an effective strategy to control the blood glucose level of diabetic patients. A novel hierarchical core-shell structure of nickel hydroxide shell coated copper hydroxide core based on copper foam (Ni(OH)@Cu(OH)-CF) was fabricated and derived from NiO@CuO-CF for glucose sensing. Cyclic voltammetry and amperometry experiments have demonstrated the efficient electrochemical catalysis of glucose under alkaline conditions.

View Article and Find Full Text PDF

Neurovascular coupling (NVC) refers to the process of local changes in cerebral blood flow (CBF) after neuronal activity, which ensures the timely and adequate supply of oxygen, glucose, and substrates to the active regions of the brain. Recent clinical imaging and experimental technology advancements have deepened our understanding of the cellular mechanisms underlying NVC. Pathological conditions such as stroke, subarachnoid hemorrhage, cerebral small vascular disease, and vascular cognitive impairment can disrupt NVC even before clinical symptoms appear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!