Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To assess the structural alterations in peri-implant bone occurring 5 years after prosthodontic loading in panoramic radiography (PR).
Methods: PR images of 44 mandibular and 33 maxillary implants along with 42 healthy control teeth taken before and 5 years after prosthodontic loading were included. Two regions-of-interest (ROI) were selected from mesial and distal surrounding bone of each implant and tooth. Then, the selected ROIs were divided to obtain three sub-ROIs (coronal, middle, and apical) on each side. A total of eight ROIs and sub-ROIs from each implant and control tooth were used for the calculations of fractal dimension (FD), lacunarity, and bone area fraction (BA/TA). The paired-sample t test was used to compare measurements before and 5 years after loading (p = 0.05).
Results: Overall evaluation of 77 implants showed that FD decreased at the middle and apical peri-implant bone levels 5 years after loading (p < 0.05). In mandibular implants, BA/TA decreased after loading (p < 0.05). While FD decreased at the coronal level (p = 0.022), lacunarity increased at the middle level of mandibular implants (p < 0.05). In maxillary implants, FD decreased at the middle and BA/TA decreased at the coronal level (p < 0.05). On the other hand, BA/TA increased at the apical level of maxillary implants (p = 0.016) after loading. None of the parameters revealed any difference in the control group (p > 0.05).
Conclusions: FD and BA/TA can be used to analyze structural changes in peri-implant bone after prosthodontic loading. Additionally, FD, lacunarity and BA/TA may provide useful information about changes occurring at different levels of peri-implant bone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11282-024-00784-0 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!