Background: This study investigated the association between segmental phase angles and functional outcomes in patients after stroke, hypothesizing that increased segmental phase angle correlates with improved functional status.
Methods: A retrospective cohort study of 1012 patients after stroke was conducted. Whole body and segmental phase angles were measured using bioelectrical impedance analysis within 3 days of admission. Our exposure of interest was segmental phase angle measured via a multifrequency bioelectrical impedance analyzer and calculated as phase angle = arctangent (Xc/R) × (180/π), where R is the resistance of the right half of the body and Xc is the reactance measured at 50 kHz. The primary outcomes were the motor subscale of the functional independence measure (FIM) at discharge and FIM change between admission and discharge. Secondary outcomes included FIM scores for specific activities. Multiple linear regression analysis was performed to assess associations.
Results: Phase angles of the healthy upper and lower limbs demonstrated stronger associations with discharge FIM motor scores (β = 0.175 and β = 0.105, respectively) and FIM motor gain (β = 0.242 and β = 0.092, respectively) compared with whole body or paretic limb phase angles. Upper limb phase angles were more closely related to grooming and toileting abilities, whereas lower limb phase angles were associated with both toileting and locomotion at discharge.
Conclusion: Segmental phase angles, particularly those of the nonparetic limbs, are promising predictors of functional outcomes in patients after stroke. Assessing segmental phase angles may guide targeted interventions and rehabilitation strategies for improving specific activities of daily living.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jpen.2703 | DOI Listing |
Anesthesiology
February 2025
McGill University, Montreal, Quebec, Canada (C.G.).
Background And Aims: Body composition parameters associated with aerobic fitness, mirrored by maximal oxygen consumption (V̇Omax), have recently gained interest as indicators of physical efficiency in facioscapulohumeral dystrophy (FSHD). Bioimpedance analysis (BIA) allows a noninvasive and repeatable estimate of body composition but is based on the use of predictive equations which, if used in cohorts with different characteristics from those for which the equation was originally formulated, could give biased results. Instead, the phase angle (PhA), a BIA raw bioelectrical parameter reflecting body fluids distribution, could provide reliable data for such analysis.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong, 999077, China.
Optical edge detection is a crucial optical analog computing method in fundamental artificial intelligence, machine vision, and image recognition, owing to its advantages of parallel processing, high computing speed, and low energy consumption. Field-of-view-tunable edge detection is particularly significant for detecting a broader range of objects, enhancing both practicality and flexibility. In this work, a novel approach-adaptive optical spatial differentiation is proposed for field-of-view-tunable edge detection.
View Article and Find Full Text PDFSci Rep
January 2025
Computational Fluid Dynamics Laboratory, School of Mechanical Engineering, VIT, Vellore, 632014, India.
Stenosis causes the narrowing of arteries due to plaque buildup, which impedes blood flow and affects flow dynamics. This work numerically analyzes flow fluctuations in stenosed arteries under realistic physiological conditions (resting and exercise) and external body acceleration. The artery is inclined at angle , and blood rheology is modeled using a generalized power-law fluid.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, Syria.
Twin block appliances are commonly used to treat skeletal class II malocclusion. However, many adverse effects, such as lower incisor protrusion and a bulky nature, can be observed. To overcome these effects, a modified twin block was designed, which uses vacuum-formed hard plates (VFPs) instead of acrylic plates.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!