Background: Scheie syndrome, an attenuated subtype of mucopolysaccharidosis type I, is a rare storage disease that causes progressive glycosaminoglycans (GAGs) accumulation. Cardiovascular disorders determine the prognosis, and cardiac valve abnormalities are the most common cause. The patients are usually young so mechanical valve replacement is often performed, but because of the features of this disease, the surgical treatment is very risky. Recently, transcatheter aortic valve implantation (TAVI) has been reported as an alternative choice for aortic stenosis, but optimal choice is still unclear. Here, we introduce a patient that underwent TAVI and refer to the histological finding of a biological valve extracted in relation to GAGs accumulation.

Case Presentation: A 54-year-old woman with Scheie syndrome underwent valve surgeries three times throughout her whole life. At age 41, she received a mitral valve replacement with a mechanical valve for mitral stenosis. She promptly developed severe diastolic dysfunction and low output syndrome after the release of aortic clamping, thus requiring temporary mechanical circulatory support. At age 51, she suffered from heart failure due to severe aortic stenosis and underwent TAVI because conventional aortic valve replacement (AVR) was deemed too risky. Three years later, her heart failure relapsed, and an echocardiogram unexpectedly revealed thickened bioprosthetic valve leaflets and a significant pressure gradient across the valve, consistent with early structural valve deterioration. AVR was performed via median sternotomy with a mechanical valve. As with the first operation, she presented refractory heart failure requiring mechanical circulatory support and was meticulously managed. However, she steadily showed worsening of multiple organ systems and died 9 days after the operation. Pathological autopsy and histological examination revealed accumulation of tissue with GAGs on the leaflets of the bioprosthetic valve of TAVI, which may have been the cause of early structural valve deterioration.

Conclusion: For patients with Scheie syndrome, a biological valve can be compromised by the accumulation of GAGs, thereby causing early SVD. These findings may support valve selection for these high-risk patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11533505PMC
http://dx.doi.org/10.1186/s44215-024-00170-6DOI Listing

Publication Analysis

Top Keywords

valve
18
scheie syndrome
16
early structural
12
structural valve
12
aortic valve
12
mechanical valve
12
valve replacement
12
heart failure
12
valve deterioration
8
transcatheter aortic
8

Similar Publications

Purpose: Infective endocarditis (IE) can be complicated by vertebral osteomyelitis (VO). This study investigates risk factors associated with VO in patients with infective endocarditis, and 6-month mortality and relapse rates in patients with IE and concomitant VO.

Methods: We performed a observational study in two hospitals between September 2016 and October 2022.

View Article and Find Full Text PDF

Left ventricular rigor mortis interferes with postmortem aortic root geometry.

Int J Legal Med

January 2025

Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.

Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.

View Article and Find Full Text PDF

Giant Sinus of Valsalva Aneurysm Obstructing Tricuspid Valve.

Radiology

January 2025

From the Department of Radiology, Mianyang Central Hospital, School of Medicine, University of Electronic Science and Technology of China, No. 12 Changjia Ln, Alarm Bell St, Fucheng District, Mianyang 621000, China.

View Article and Find Full Text PDF

Characterization of a simple gas expansion ion source for intense pulses of subthermal molecular ions.

Rev Sci Instrum

January 2025

Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany.

We describe a simple gas expansion ion source based on static discharge voltages and a commercially available pulsed valve. The discharge is initiated by the gas pulse itself between two high voltage electrodes, without the need for fast voltage switches or complex timing schemes. The ion source very reliably produces intense bursts of molecular ions (with currents exceeding 100 μA during the pulse-on phase) with only minor pulse-to-pulse variations in intensity and pulse shape.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!