AI Article Synopsis

  • - The study examines the safety and efficacy of a new 8F variable loop multielectrode catheter for pulsed field ablation (PFA) in patients with atrial fibrillation, which simplifies catheter use compared to earlier complex designs.
  • - Out of 30 patients, all achieved complete pulmonary vein and posterior wall isolation, with an average procedural time of about 113 minutes and minimal complications, including a few transient cerebral lesions.
  • - The research highlights that this new catheter system provides effective PFA while maintaining a safety profile similar to existing options, showing promise for future use in treating atrial fibrillation.

Article Abstract

Background: Different iterations of catheter and energy delivery system configurations are evolving for pulsed field ablation (PFA); however, some have used large and complex catheters, required large sheaths, and had a recognized risk of hemolysis.

Objective: The purpose of this study was to evaluate the acute safety and efficacy of a custom designed 8F variable loop multielectrode mapping and PFA catheter with contact sensing.

Methods: This acute feasibility study recruited 30 patients undergoing de novo ablation of paroxysmal or persistent atrial fibrillation (AF). The ElectroPulse Study is a first-in-human, nonrandomized, prospective study of a novel PFA system that utilizes an 8F, 10-electrode variable loop steerable mapping and ablation catheter with 2800-V biphasic bipolar waveform. All patients had pulmonary vein isolation (PVI) and posterior wall isolation (PWI) using the PFA system. The main outcomes were the acute success of PV/PWI and periprocedural serious adverse events.

Results: Complete PVI/PWI was successfully achieved in all 30 patients using 59.7 ± 7.2 applications. Total procedural time was 113.6 ± 26.3 minutes, fluoroscopy time 8.0 ± 5.5 minutes, and left atrial dwell time 78.7 ± 18.6 minutes. There was no esophageal injury, phrenic nerve palsy, clinical stroke, or death. Brain magnetic resonance imaging detected 2 new but transient silent cerebral lesions. Two patients (6.7%) had vascular access complications. Although there were changes in the biomarkers for hemolysis, none of the patients experienced clinical hemolysis or related acute kidney injury.

Conclusion: This first-in-human study demonstrated that PFA using a novel variable loop catheter with a contact sensing system safely achieved 100% acute PVI/PWI with safety profile comparable to existing PFA systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2024.10.070DOI Listing

Publication Analysis

Top Keywords

variable loop
12
pulsed field
8
field ablation
8
posterior wall
8
wall isolation
8
catheter contact
8
pfa system
8
acute
6
pfa
6
study
5

Similar Publications

Brain stimulation has, for many decades, been considered as a potential solution for the unmet needs of the many people living with drug-resistant epilepsy. Clinically, there are several different approaches in use, including vagus nerve stimulation (VNS), deep brain stimulation of the thalamus, and responsive neurostimulation (RNS). Across populations of patients, all deliver reductions in seizure load and SUDEP risk, yet do so variably, and the improvements seem incremental rather than transformative.

View Article and Find Full Text PDF
Article Synopsis
  • SARS-CoV-2 continues to pose challenges globally, with new variants like Omicron affecting the efficacy of potential preventative treatments such as Hesperidin (HD).
  • The study focuses on how various mutations in the Omicron variant influence HD's binding and energetics within the SARS-CoV-2 spike receptor complex, particularly analyzing eight point mutations.
  • Findings reveal that specific mutations like S477N enhance HD stability and interactions, while others like Y505H destabilize the complex, indicating that mutations impact HD's effectiveness through varying mechanisms such as bonding and molecular flexibility.
View Article and Find Full Text PDF

The chloride transporter-channel SLC26A9 is mediated by a reciprocal regulatory mechanism through the interaction between its cytoplasmic STAS domain and the R domain of CFTR. In vertebrate Slc26a9s, the STAS domain structures are interrupted by a disordered loop which is conserved in mammals but is variable in non-mammals. Despite the numerous studies involving the STAS domains in SLC26 proteins, the role of the disordered loop region has not been identified.

View Article and Find Full Text PDF

Serial Dependence in Smooth Pursuit Eye Movements of Preadolescent Children and Adults.

Invest Ophthalmol Vis Sci

December 2024

School of Psychology and Cognitive Science, East China Normal University, Shanghai, China.

Purpose: Serial dependence refers to the attraction of current perceptual responses toward previously seen stimuli. Despite extensive research on serial dependence, fundamental questions, such as how serial dependence changes with development, whether it affects the perception of sensory input, and what qualifies as serial dependence, remain unresolved. The current study aims to address these questions.

View Article and Find Full Text PDF

Biomimetic Linkage Mechanism Robust Control for Variable Stator Vanes in Aero-Engine.

Biomimetics (Basel)

December 2024

The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.

This work addresses the position tracking control design of the stator vane driven by electro-hydrostatic actuators facing uncertain aerodynamic disturbances. Rapidly changing aerodynamic conditions impose complex disturbance torques on the guide vanes. Consequently, a challenging task is to enhance control precision in complex uncertain environments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!