A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of the connection structure of zirconia dental implants on biomechanical properties. | LitMetric

Effect of the connection structure of zirconia dental implants on biomechanical properties.

J Mech Behav Biomed Mater

School of Mechanical Engineering and Automation, Northeastern University, Shenyang, 110004, China. Electronic address:

Published: January 2025

AI Article Synopsis

  • * Four connection types were tested: triangular, quadrilateral, hexagonal, and hexalobular plus, using finite element analysis for static load, bone level, and torsion models.
  • * Results showed the hexagonal structure had the highest stress in static tests, while the hexalobular plus connection performed best overall, especially in bone stress distribution and torsion tests, making it the recommended choice for implants.

Article Abstract

The connection structure of zirconia dental implants significantly influences their biomechanical behavior and plays a crucial role in the overall service performance of the implant system. This study aims to compare the stress distribution of zirconia implants featuring various internal connection structures under different working conditions. Four distinct types of connection structures were designed for zirconia dental implants: triangular, quadrilateral, hexagonal, and hexalobular plus connections. Additionally, the finite element method was employed to analyze these structures under three working conditions: a static load test model, a bone level model, and a torsion model. Results indicated that in the static load test model, the hexagonal structure experienced the highest stress value at 1284.9 MPa due to its thin neck wall, whereas the hexalobular plus connected implant exhibited the lowest stress value at 1252.9 MPa. In the bone level model, the triangular connection structure demonstrated poor stress distribution for cortical bone and cancellous bone at 69.606 MPa and 7.8191 MPa, respectively. Conversely, the hexalobular plus connection yielded superior stress results for cortical bone and cancellous bone, with values of 66.24 MPa and 5.1327 MPa, respectively. In the torsion model, the hexalobular plus-connected implant exhibits the highest stress value at 237.6 MPa, while maintaining the smallest force transmission angle. Therefore, given that the abutment necessitates a greater range of installation angles and improved torque transmission, the hexalobular plus connection structure may represent the optimal choice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2024.106800DOI Listing

Publication Analysis

Top Keywords

connection structure
16
zirconia dental
12
dental implants
12
structure zirconia
8
stress distribution
8
connection structures
8
working conditions
8
static load
8
load test
8
test model
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!