A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design and testing of an (inert) gas cell for in situ polarization modulation infrared reflection absorption spectroscopic (PM-IRRAS) measurements under specific atmospheres. | LitMetric

AI Article Synopsis

  • IRRAS is an analytical technique used to study molecules adsorbed on metal surfaces, even at low coverage levels.
  • A new inert gas cell has been developed to enhance the Bruker PMA50 module, allowing for measurements of thin films in a controlled atmosphere and enabling the transfer of samples into a glovebox.
  • The study demonstrates the use of this gas cell to observe the reaction of an air-sensitive molybdenum complex on a gold surface, showing that light exposure accelerates its conversion to a different chemical form.

Article Abstract

Infrared reflection absorption spectroscopy (IRRAS) is a powerful surface-sensitive analytical technique to characterize the adsorbed molecules on metal surfaces down to (sub)monolayer coverage. In this paper, a new (inert) gas cell is presented that expands the scope of the commercially available Bruker PMA50 module. The cell is designed as a sample holder to measure thin films of molecules adsorbed on a metal substrate under a specific gaseous atmosphere. The dimensions of the cell are chosen in such a way that it can be transferred into a glovebox via the standard entrance port (Ø150 mm), allowing the investigation of air-sensitive molecules under an inert-gas atmosphere. The cell has two hose connections through which the gas atmosphere can be varied as desired. This also allows for studying the reactivity of the adsorbed structures toward the surrounding gas in situ and in a (potentially) time-dependent fashion. Furthermore, the metal substrate can be irradiated via an exposure window to investigate the influence of light on the adsorbed molecules and/or their reactivity. Using the polarization-modulation (PM-) IRRAS technique along with the described gas cell, an air-sensitive molybdenum(0) tricarbonyl complex adsorbed on an Au(111) surface is investigated. This complex reacts with molecular oxygen to the molybdenum(VI) trioxo analog, and this conversion is accelerated by irradiation with light of 365 and 440 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0227001DOI Listing

Publication Analysis

Top Keywords

gas cell
12
inert gas
8
infrared reflection
8
reflection absorption
8
adsorbed molecules
8
metal substrate
8
cell
6
gas
5
adsorbed
5
design testing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!