Purpose: Studies about success of FPDs (fixed partial dentures) mostly include restorations built by different clinicians. This results in limited comparability of the data. The aim of this study was to evaluate complications of all-ceramic FPDs built by 1 dentist between 2011 to 2023.
Materials And Methods: 342 all-ceramic FPDs were observed during follow-up care. 48 patients received 262 single crowns, 59 bridges and 21 veneers. Because of the different lengths of the bridges, units were defined as restored or replaced tooth. 465 units performed by the same dentist from Nov 2011 to Nov 2022 were included. Influencing factors "restoration", "construction", "abutment", "localization", "vitality" and "application period" were evaluated using Kaplan-Meier Analysis and Log-Rank Tests.
Results: 406 units (87.3 %) showed no complication. 7 correctable chippings (1.5 %) and 10 recementable decementations (2.1 %) occurred. Six decemented units got lost (1.3 %). 21 units failed due to fatal fracture (4.5 %). Crown margin complications, such as secondary caries, occurred in 15 units (3.2 %). Comparing the influencing factors resulted in higher complication rates of veneers ( < .001), of monolithic ceramics (P ≤ .050) and of molar-restorations ( = .047). The application period had no influence on the success and survival rate.
Conclusion: Overall, all-ceramic FPDs showed good clinical results. Although less complications were observed with modern restorations, these more often led to complete failure. To generate evidence-based recommendations, further studies are needed to evaluate the mid- and short-term success and survival of current all-ceramic restorations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538893 | PMC |
http://dx.doi.org/10.4047/jap.2024.16.5.267 | DOI Listing |
J Adv Prosthodont
October 2024
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.
Purpose: Studies about success of FPDs (fixed partial dentures) mostly include restorations built by different clinicians. This results in limited comparability of the data. The aim of this study was to evaluate complications of all-ceramic FPDs built by 1 dentist between 2011 to 2023.
View Article and Find Full Text PDFAlthough CAD/CAM (computer-aided design/computer-aided manufacturing) restorations act as a favorable alternative to conventional metal-ceramic restorations for fixed dental prostheses, little is known about their intermediate and persistent clinical performance. This systematic review and meta-analysis aimed to assess the clinical performance in terms of biological, technical, and esthetic aspects and the survival and success ratios for single full crowns (SFCs) and fixed partial dentures (FPDs) fabricated by CAD/CAM and conventional techniques and according to the materials used (zirconia {ZC} and lithium disilicate {LD}). The population, intervention, control, outcome, and study design (PICOS) strategy was used to electronically search key terms in the PubMed, Cochrane Library, Embase, and Wiley Online databases for randomized control trials (RCTs) and cohort studies.
View Article and Find Full Text PDFIntroduction: Masticatory pressure increases in the distal areas of the dentition. This should be considered when restoring partially edentulous patients with a metal-free fixed partial denture (FPD). An alternative abutment preparation design can be used in order to increase the materials' volume in the most fracture-prone "connector area" of an FPD.
View Article and Find Full Text PDFMed J Armed Forces India
September 2022
Commandant, Command Military Dental Centre (Western Command), Chandimandir, Haryana, India.
Background: Fixed dental prostheses have been provided in the Armed Forces for a long time, yet definite evidence-based guidelines on the success and failure of different types of prostheses are currently lacking. A cross-sectional observational study was conducted as a step towards addressing this lacuna.
Methods: The study included 156 patients and 538 prostheses based on pre-established inclusion criteria.
Biology (Basel)
April 2022
Department of Prosthodontics, Faculty of Dental Medicine, "Iuliu Haţieganu" University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania.
The metal-ceramic fixed partial prosthesis is the golden standard for posterior tooth restorations. Following the demands of patients and clinicians for metal-free restorations, all-ceramic materials were developed as they offer an adequate alternative with better optical qualities and good mechanical properties. This study aims to carry out a bibliographic review to assess the survival rate and the biological and technical complications of all-ceramic and metal-ceramic fixed partial dentures.