A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of Intraoperative Visual Evoked Potentials for Inclusion of Unstable Electroretinograms. | LitMetric

Purpose: The objectives of the study were to evaluate the validity of intraoperative flash visual evoked potentials (VEPs) when electroretinograms (ERGs) were unstable, to compare white versus red light-emitting diodes, and to assess the impact of luminance on ERG variability.

Methods: Thirty patients were included (Inomed system; pre- and postoperative visual fields). Possible changes in visual fields were assessed with mean defects in perimetry. The receiver operating characteristic (ROC) curves of normalized VEPs and of normalized and corrected VEPs with ERGs were compared.

Results: Thirty-two eyes could be analyzed in 20 patients (mainly gliomas and meningiomas): 2 had a severe defect in their visual field, and 6 had a mild defect. The receiver operating characteristic curve indicated (1) normalized and corrected VEPs with ERGs were more reliable than normalized VEPs only (P < 0.03) and (2) an alarm threshold of 80% of normalized and corrected VEPs. No significant difference in variability of ERGs was found with white or red light-emitting diodes with this system. Increased luminance improved stability of ERGs (P < 0.05).

Conclusions: Normalization and correction of VEPs with ERGs improved the validity of VEPs and indicated a 20% decrease as alarm criterion. This normalization and correction with peripheral excitation could be generalized to improve the reliability of neuromonitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1097/WNP.0000000000001129DOI Listing

Publication Analysis

Top Keywords

normalized corrected
12
corrected veps
12
veps ergs
12
visual evoked
8
evoked potentials
8
veps
8
red light-emitting
8
light-emitting diodes
8
visual fields
8
receiver operating
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!