Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A highly sensitive and selective label-free impedimetric immunosensor based on AuNPs@pDA@NiCoS@MoS nanocomposite modified on the surface of a screen-printed electrode (SPE) was designed for the detection of interleukin-6 (IL-6). The distribution of NiCoS nanoparticles on MoS nanosheets was able to prevent them from agglomerating. The polydopamine (pDA) layer was coated on the surface of NiCoS@MoS nanosheets by self-polymerization, which improved the stability and biocompatibility of the nanomaterial. The excellent reduction ability of pDA promoted the synthesis of gold nanoparticles (AuNPs), which increased the amount of antibody adsorption and the conductivity of the material. Finally, the antibody (Ab) of IL-6 was immobilized on the surface of AuNPs@pDA@NiCoS@MoS nanocomposite. Electrochemical impedance spectroscopy (EIS) was used to detect the change of impedance before and after the immune response between Ab and IL-6 antigen (IL-6). Under the optimal experimental conditions, the relative change in impedance and the logarithmic concentration of IL-6 showed a good linear relationship in the range 1.00 to 1.00 × 10 pg/mL, with a low detection limit of 0.97 pg/mL. In addition, the proposed immunosensor performed with good reproducibility, stability, and specificity. It was successfully applied to the determination of IL-6 in patient's serum samples of head and neck carcinoma with recoveries of 98.40% to 106.5%. To sum up, the proposed label-free impedimetric immunosensor was successfully constructed for IL-6 detection in real samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00604-024-06779-2 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!