A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Cyanoacrylate Tissue Adhesive Glue Application Outcomes in Corneal Thinning and Perforation. | LitMetric

Evaluation of Cyanoacrylate Tissue Adhesive Glue Application Outcomes in Corneal Thinning and Perforation.

Eye Contact Lens

College of Medicine (S.S., S.K., A.O.), University of Florida, Gainesville, FL; Department of Ophthalmology (L.J., S.T., A.S.), College of Medicine, University of Florida, Gainesville, FL; and Division of Ophthalmology (A.S.), Department of Veterans Affairs, Salem VA Medical Center, Salem, VA.

Published: November 2024

Objectives: Corneal thinning and perforation are ocular emergencies necessitating urgent intervention to prevent visual impairment or enucleation. Cyanoacrylate tissue adhesive is frequently used to maintain globe integrity in these cases. However, gaps remain in understanding the outcomes of corneal gluing and the factors influencing its efficacy. This case series evaluates the clinical characteristics and outcomes of glue application in corneal thinning and perforation.

Methods: A retrospective chart review was conducted on patients treated for corneal thinning and perforation at the University of Florida between January 2012 and May 2023. Demographic data, clinical history, glue application details, and posttreatment outcomes were collected and analyzed.

Results: The study included 128 eyes from 125 subjects. Corneal perforation was found in 71 eyes (55.5%), mostly centrally (49.2%). The leading cause of perforation/thinning was microbial infection (45.3%). The average number of glue applications per eye was 1.66. Within 1 month, 23 patients (18.0%) required only glue reapplication, 37 (28.9%) required surgical intervention (regardless of glue reapplication), and 68 (53.1%) required no further treatment. Factors significantly linked to gluing failure (requiring surgery within 1 month) in univariate analysis included large perforation size, microbial infection, ocular surface disorder, single glue application, and indirect application via sterile drape. Multivariate analysis showed that only large perforation size was significantly associated with gluing failure.

Conclusion: Corneal glue application is an effective temporizing measure for corneal thinning and perforation, with multiple applications potentially providing added stability to the globe. However, the need for surgical intervention is high.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0000000000001144DOI Listing

Publication Analysis

Top Keywords

glue application
20
corneal thinning
20
thinning perforation
16
cyanoacrylate tissue
8
tissue adhesive
8
glue
8
corneal
8
outcomes corneal
8
microbial infection
8
glue reapplication
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!