The Tesla-type pulsed power generator based on transformer oil is limited by volume and weight, which affects its suitability for mobile platforms. In this paper, a double-width pulse forming line (PFL) based on high-energy-density liquid medium Midel 7131 was designed, and a compact, high-repetitive pulsed power generator was developed. The structural and electrical parameters of the PFL with an outer diameter of 1000 mm were optimized to achieve the highest output power with a fixed load impedance of 60 Ω. This generator employed a double-width forming line, which has an output pulse width of four times of the electrical length of its external line, significantly increasing the output pulse width and making the system more compact. The generator could be finally enveloped with a size of 4 × 1.5 × 1.5 m3 and a weight of 4.7 tons. The experiment showed that the generator could operate reliably under the conditions of 15-GW peak power, 50-ns pulse width, 50-Hz repetition rate, and <1% voltage jitter. The X-band relatively backward wave oscillator driven by this generator yielded a favorable microwave, which demonstrated the high-power driving capability of the generator.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0202377 | DOI Listing |
BMC Sports Sci Med Rehabil
January 2025
Idaho College of Osteopathic Medicine, 1401 E. Central Dr, Meridian, ID, 83642, USA.
Background: "Active" heat acclimation (exercise-in-the-heat) can improve exercise performance but the efficacy of "passive" heat acclimation using post-exercise heat exposure is unclear. Therefore, we synthesised a systematic review and meta-analysis to answer whether post-exercise heat exposure improves exercise performance.
Methods: Five databases were searched to identify studies including: (i) healthy adults; (ii) an exercise training intervention with post-exercise heat exposure via sauna or hot water immersion (treatment group); (iii) a non-heat exposure control group completing the same training; and (iv) outcomes measuring exercise performance in the heat (primary outcome), or performance in thermoneutral conditions, V̇Omax, lactate threshold, economy, heart rate, RPE, core temperature, sweat rate, and thermal sensations.
Eur J Appl Physiol
January 2025
Department of Kinesiology and Health Promotion, University of Kentucky, 1210 University Drive, Lexington, KY, 40526, USA.
Purpose: The purpose of this study was to examine the sex-specific influence of expected exercise duration on the physiological responses to RPE-clamp exercise anchored to RPE 15 with participants being deceived into believing the RPE-clamp exercise would last for 20-, 30-, or 40-min, but all trials were 30-min.
Methods: Twelve males and 12 females completed a graded exercise test followed by randomly ordered RPE-clamp trials at RPE15 on the Borg 6-20 scale where subjects were deceived into expecting exercise to last for either 20-, 30-, or 40-min, but the actual duration for each trial was 30-min. Separate 2 (Sex [Male vs.
Sci Rep
January 2025
INFN-Laboratori Nazionali di Frascati, Via E. Fermi, 54, 00044, Frascati, Italy.
We analytically solve the Landau-Lifshitz equations for the collective magnetization dynamics in a synthetic antiferromagnet (SAF) nanoparticle and uncover a regime of barrier-free switching under a short small-amplitude magnetic field pulse applied perpendicular to the SAF plane. We give examples of specific implementations for forming such low-power and ultra-fast switching pulses. For fully optical, resonant, barrier-free SAF switching we estimate the power per write operation to be pJ, 10-100 times smaller than for conventional quasi-static rotation, which should be attractive for memory applications.
View Article and Find Full Text PDFJ Electr Bioimpedance
January 2024
Electrical Engineering Department, State University of Santa Catarina, Santa Catarina, Brazil.
Wearable and portable devices are gaining significant popularity across consumer electronics as well as in medical and industrial fields. To ensure that these devices are both comfortable and appealing to users, they need to have low battery consumption and be compact in both size and weight. The EGluco project is focused on developing a wearable device for non-invasive blood glucose monitoring.
View Article and Find Full Text PDFACS Omega
December 2024
Shenmu Ningtiaota Mining Company, Shaanxi Coal and Chemical Industry Group, Shenmu, Shaanxi 719300, China.
Given that conducting controllable shock wave tests in actual rock formations underground in coal mines affects coal mine production with the parameters required for equipment design and incurs significant costs, a series of ground tests were conducted separately. First, the impact of energy storage on rock breaking efficiency was analyzed. Then, physical simulation experiments were conducted on the differential efficiency of controllable shock waves on high-strength cement, sandstone, granite, solid granite, and limestone.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!