A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dual "Turn-On" Fluorescent and Colorimetric Sensing of Permanganate Based on Yellow Carbon Dots. | LitMetric

AI Article Synopsis

  • Existing methods for detecting permanganates have issues like poor selectivity and solubility, leading to false positives.
  • This study introduces a new "turn-on" fluorescence method using yellow fluorescence carbon dots (Y-CDs) that significantly increase their fluorescence when MnO is present.
  • The technique allows for both fluorescence and colorimetric analysis, providing a reliable way to detect MnO in complex environments by confirming results through two different sensing methods.*

Article Abstract

Existing permanganates (MnO ) sensing methods suffered from the poor selectivity, restricted solubility, and/or less desirable signaling mechanisms (e.g., "turn-off" processes), resulting in the false positive result. In this work, an effective "turn-on" fluorescence method for MnO detection in aqueous media was proposed via yellow fluorescence carbon dots (Y-CDs) with the maximum emission peak of 553 nm. Upon the introduction of MnO , the fluorescence of Y-CDs increased significantly due to the enhanced surface passivation degree and intramolecular charge transfer. In the range of 0.1-10 μM, the fluorescence ratio (F/F) is proportional to the MnO ions concentration, realizing the "turn-on" fluorescence sensing of MnO . On the other hand, utilizing the significant color change of Y-CDs by MnO ions, the colorimetric analysis can also be established for MnO assay. Compared with other probes, the analysis results obtained by bimodal sensing tactics of fluorescent and colorimetric can be mutually verified to improve the reliability and meet the sensing needs of targets in complex environments.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bio.70011DOI Listing

Publication Analysis

Top Keywords

fluorescent colorimetric
8
carbon dots
8
"turn-on" fluorescence
8
mno ions
8
mno
7
sensing
5
fluorescence
5
dual "turn-on"
4
"turn-on" fluorescent
4
colorimetric sensing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!