Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Alkaline phosphatase (ALP) is an indispensable hydrolase in living organisms and the abnormality of ALP activity is correlated with a variety of diseases. Exploring ALP activity is important for clinical diagnosis and biomedical research to understand its physiological function. In this study, a dual-mode biosensing platform was constructed based on Cu-based metal-organic frameworks (Cu-MOFs) for electron spin resonance (ESR) and ultraviolet-visible (UV-vis) sensing of ALP. Cu-MOFs, as peroxidase mimics, catalyzed the decomposition of hydrogen peroxide (HO) and the generation of reactive oxygen species (ROS) which could oxidize ABTS into ABTS˙ with good ESR and UV-vis signals. Pyrophosphate ions (PPi) with high affinity to Cu in Cu-MOFs could suppress the peroxidase-like activity of Cu-MOFs, and ALP could hydrolyze PPi, resulting in the recovery of Cu-MOF catalytic activity. Thus, a quantitative dual-mode method for detection of ALP activity was established with good linearity in the range of 0-42 U L and limits of detection as low as 0.386 and 0.523 U L respectively for ESR and UV-vis detection. Benefiting from its high sensitivity and excellent selectivity, this method was applied for ALP detection in human serum and satisfactory recoveries were achieved. The off-on dual-mode sensing platform is more reliable than the single-mode sensor and shows merits like simple operation and cost-friendliness, making it have great potential in the diagnosis of ALP-related diseases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d4ay01682c | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!