Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Lumbar medial branch (MB) radiofrequency ablation is a common intervention to treat facetogenic low back pain. The consensus among spine pain interventionalists is that capturing a greater length of the MB correlates with a longer duration of pain relief. Therefore, there has been interest in defining optimal needle angles to achieve parallel cannula placement. Presently, there is inconsistency regarding the optimal caudal needle angles.
Objectives: The objectives of this study were to: 1) use a dissection-based 3D modelling methodology to quantify optimal caudal needle angles from cadaveric models; and 2) compare optimal cadaver-derived caudal needle angles with real-world patient-derived needle angles.
Methods: Eighteen formalin embalmed lumbosacral spine specimens were dissected, digitized, and modelled in 3D. Virtual needles were simulated and placed parallel with the L1-L5 MBs. Cadaver-derived caudal needle angles were measured from the high-fidelity 3D models with optimally placed virtual needles. Lateral fluoroscopic images of patients (n = 200) that received lumbar MB denervation were reviewed to measure patient-derived caudal needle angles (L3-L5 MB levels). Descriptive statistics were used to analyze the cadaver (L1-L5 MB levels) and patient-derived (L3-L5 MB levels) caudal needle angles. The cadaver and patient-derived mean caudal needle angles for L3-L5 MB levels were compared.
Results: There was variability in the cadaver-derived mean caudal needle angles. The lowest mean caudal needle angle was the L1 MB level measured at 41.57 ± 8.56° (range: 27.14° - 53.96°). The highest was the L5 MB level with a mean caudal needle angle of 60.79 ± 8.55° (range: 46.97° - 79.74°). A total of 123 patients were included and 369 caudal needle angles (L3-L5 MB levels) were measured and analyzed. There was variability in the patient-derived mean caudal needle angles. The patient-derived mean caudal needle angles were 29.18 ± 8.77° (range: 11.80° - 61.31°), 33.34 ± 7.23° (range: 16.40° - 54.15°), and 49.08 ± 8.87° (range: 26.45° - 76.95°) for the L3, L4, and L5 MB levels, respectively. There was a significant difference in mean caudal needle angle between cadaver and patient-derived needle angles at the L3, L4, and L5 MB levels.
Conclusions: Analysis of cadaver-derived needle angles versus patient-derived data suggests optimization of lumbar MB denervation requires greater caudal angulation to achieve parallel needle placement. Further research is required to assess the clinical implications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11536316 | PMC |
http://dx.doi.org/10.1016/j.inpm.2024.100433 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!