A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research. | LitMetric

Background: Patient-specific instruments (PSIs) were reported to improve implant position and rotation accuracy in total knee arthroplasty (TKA), among other benefits. Most PSIs used in TKA were commercial products from implant manufacturers, which could be time-consuming and could potentially affect accuracy as they relied on engineer's decision. This study aimed to present the radiological outcomes of PSI produced by the 3D printing facility at our hospital, with direct involvement of the surgeon in its design.

Methods: This prospective study enrolled 45 patients who underwent mechanically aligned TKA. Preoperative whole-limb 3D-CT scans were obtained to create the sizing plan. The surgeon identified the position of the cut plane and guide pin locations on software, which were then forwarded to engineers for further processing. Subsequently, the PSI was fabricated using in-hospital 3D resin printers. During surgery, after removing all remaining cartilage, the PSI was utilized on the bone surfaces to assist surgeons in drilling pinhole positions for the manufacturer's cutting instruments. Post-surgery, CT scans were acquired and overlaid onto the 3D model of the implant to compare to the plan.

Results: On average, it took three days to prepare for the surgery using PSI. 100 % of patients had implant sizes that matched the preconception template. The mean postoperative hip-knee angle was 178.1° ± 1.34°. The mean femoral component rotation angle relative to the surgical transepicondylar axis (sTEA) and the mean rotation mismatch between the femur and tibial component were 0.99° ± 0.84° and 0.91° ± 1.61°, respectively.

Conclusions: Preliminary radiological results demonstrated that in-hospital PSI was a useful technique for improving the accuracy of implant positioning in TKA, especially in controlling the rotational alignment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11532799PMC
http://dx.doi.org/10.1016/j.jor.2024.10.032DOI Listing

Publication Analysis

Top Keywords

accuracy total
8
total knee
8
knee arthroplasty
8
implant
5
psi
5
accuracy
4
arthroplasty hospital-based
4
hospital-based printed
4
printed patient-specific
4
patient-specific instrumentation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!