Deep convolutional neural networks (DCNNs) are remarkably accurate models of human face recognition. However, less is known about whether these models generate face representations similar to those used by humans. Sensitivity to facial configuration has long been considered a marker of human perceptual expertise for faces. We tested whether DCNNs trained for face identification "perceive" alterations to facial features and their configuration. We also compared the extent to which representations changed as a function of the alteration type. Facial configuration was altered by changing the distance between the eyes or the distance between the nose and mouth. Facial features were altered by replacing the eyes or mouth with those of another face. Altered faces were processed by DCNNs (Ranjan et al., 2018; Szegedy et al., 2017) and the similarity of the generated representations was compared. Both DCNNs were sensitive to configural and feature changes-with changes to configuration altering the DCNN representations more than changes to face features. To determine whether the DCNNs' greater sensitivity to configuration was due to a priori differences in the images or characteristics of the DCNN processing, we compared the representation of features and configuration between the low-level, pixel-based representations and the DCNN-generated representations. Sensitivity to face configuration increased from the pixel-level image to the DCNN encoding, whereas the sensitivity to features did not change. The enhancement of configural information may be due to the utility of configuration for discriminating among similar faces combined with the within-category nature of face identification training.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11542502 | PMC |
http://dx.doi.org/10.1167/jov.24.12.6 | DOI Listing |
Microsc Res Tech
January 2025
Department of Anatomy, Erciyes University Faculty of Veterinary Medicine, Kayseri, Türkiye.
In this study, the kidneys of ground squirrels (hibernated and nonhibernated), rabbits, and rats were examined macro and microanatomically. Kidney morphology was investigated by stereo microscopy, light microscopy, and scanning electron microscopy. Triple and immunohistochemical staining were performed for light microscopic examinations.
View Article and Find Full Text PDFNatl Sci Rev
January 2025
School of Physics, State Key Laboratory of Crystal Materials, Shandong University, Jinan 250100, China.
The incorporation of polymeric insulators has led to notable achievements in the field of organic semiconductors. By altering the blending concentration, polymeric insulators exhibit extensive capabilities in regulating molecular configuration, film crystallinity, and mitigation of defect states. However, current research suggests that the improvement in such physical properties is primarily attributed to the enhancement of thin film morphology, an outcome that seems to be an inevitable consequence of incorporating insulators.
View Article and Find Full Text PDFFront Health Serv
December 2024
Department of Biomedical Informatics, University of Arkansas for Medical Sciences, Little Rock, AR, United States.
Introduction: Clinicians are the conduits of high-quality care delivery. Clinicians have driven advancements in pharmacotherapeutics, devices, and related interventions and improved morbidity and mortality in patients with congestive heart failure over the past decade. Yet, the management of congestive heart failure has become extraordinarily complex and has fueled recommendations from the American Heart Association and the American College of Cardiology to optimize the composition of the care team to reduce the health, economic, and the health system burden of high lengths of stay and hospital charges.
View Article and Find Full Text PDFPurpose: To theoretically and experimentally study implant lead tip heating caused by radiofrequency (RF) power deposition in different wire configurations that contain loop(s).
Methods: Maximum temperature rise caused by RF heating was measured at 1.5T on 20 insulated, capped wires with various loop and straight segment configurations.
Front Neurosci
December 2024
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Introduction: Traditional extraocular electrical stimulation typically produces diffuse electric fields across the retina, limiting the precision of targeted therapy. Temporally interfering (TI) electrical stimulation, an emerging approach, can generate convergent electric fields, providing advantages for targeted treatment of various eye conditions.
Objective: Understanding how detailed structures of the retina, especially the optic nerve, affects electric fields can enhance the application of TI approach in retinal neurodegenerative and vascular diseases, an essential aspect that has been frequently neglected in previous researches.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!