On some occasions, such as new energy clinics, monitoring the trace hydrogen at the ppb level is necessary. The traditional resistive hydrogen sensors based on the Pd alloys are very difficult to realize such an extremely low detection limit. To achieve a detection limit at the ppb level and also ensure good stability, a MEMS hydrogen sensor was designed in a suspended Wheatstone bridge structure, with all four resistive arms defined on a sputtered Pd-Au alloy thin film. For the Wheatstone bridge sensor, absolute response () and relative response () are defined to describe the sensitivity of the sensor, and the effect of annealing temperature on baseline drift is investigated using the baseline zero drift parameter (DBZD). By testing the sensors across a hydrogen concentration range of 20 ppb to 3 v/v%, the optimal annealing temperature (250 °C) and operating temperature (60 °C) were identified. Under these conditions, the sensor exhibited a detection limit as low as 20 ppb with a power consumption of only 4.6 mW. At the same time, the response and recovery times of the sensor were 6 and 19 s, respectively, toward 3 v/v% hydrogen. After testing over a 100-day period, fluctuated only 0.0026%, indicating that the hydrogen sensor had good long-term stability for low-concentration detection. More results also showed that the sensor has good repeatability, selectivity, and humidity resistance. With the wide measurement range (20 ppb to 3 v/v%), the sensor has the potential to meet hydrogen detection requirements in multiple scenarios.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acssensors.4c01964 | DOI Listing |
J Infect Chemother
January 2025
Division of Microbiology, Department of Pathology and Microbiology, Nihon University School of Medicine, Tokyo, Japan. Electronic address:
The BioFire FilmArray® Gastrointestinal (GI) Panel, a widely used diagnostic tool, is designed to detect the genetic material of 22 common pathogens responsible for gastroenteritis, including viruses, bacteria, and parasites. It can detect human adenovirus (HAdV) species F, particularly serotypes F40 and F41, which are the major causes of diarrhea and mortality in children. However, its potential shortcomings in detecting other HAdV species limit its effectiveness in broader HAdV detection in clinical settings and outbreak investigations.
View Article and Find Full Text PDFBiosens Bioelectron
December 2024
Biophotonic Nanosensors Laboratory, Centro de Física Aplicada y Tecnología Avanzada (CFATA), Universidad Nacional Autónoma de México (UNAM), Querétaro, 76230, Mexico. Electronic address:
Smartphone-based colorimetric (bio)sensing is a promising alternative to conventional detection equipment for on-site testing, but it is often limited by sensitivity to lighting conditions. These issues are usually avoided using housings with fixed light sources, increasing the cost and complexity of the on-site test, where simplicity, portability, and affordability are a priority. In this study, we demonstrate that careful optimization of color space can significantly boost the performance of smartphone-based colorimetric sensing, enabling housing-free, illumination-invariant detection.
View Article and Find Full Text PDFFood Chem
January 2025
State Key Laboratory for Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China. Electronic address:
Heavy metals and mycotoxins are important contaminants in food pollution. Sensitive, reliable, and rapid detection of heavy metals and mycotoxins is crucial for human health. In this work, imidazole-functionalized aggregation-induced emission (AIE) molecule tetra-(4-pyridylphenyl) ethylene (TPPE) was used as a precise and specific probe for Ag detection, with a limit of detection (LOD) of 0.
View Article and Find Full Text PDFTalanta
January 2025
Department of Materials and Environmental Technology, Tallinn University of Technology, Ehitajate tee 5, 19086, Tallinn, Estonia. Electronic address:
Ampicillin (AMP) ranks third among the top ten most frequently sold antibiotic combinations globally, raising concerns due to its extensive use. Improper disposal practices in agriculture, aquaculture, and healthcare have led to environmental contamination of water sources with elevated AMP levels. Current methods for detecting such contamination are costly, require sophisticated equipment, and depend on skilled personnel and unstable natural receptors.
View Article and Find Full Text PDFJ Colloid Interface Sci
January 2025
State Key Laboratory of New Pharmaceutical Preparations and Excipients, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University 071002 Baoding, PR China. Electronic address:
In this study, a Co doped polyhedral carbon skeleton (Co CN) was prepared by nitrogen carbonization using ZIF-67 as a precursor. The Co CN features a rough surface with excellent electrical conductivity, and the Co atoms exhibit unique catalytic properties. Based on these characteristics, we used Co CN as a carrier to load Au nanoparticles (NPs) onto its surface through the linkage and reduction effects of polyoxometalates (POMs).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!