A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Maximum Isokinetic Eccentric Elbow Flexor Muscle Force Can Be Estimated Using Maximum Isometric Contraction Force. | LitMetric

Purpose It is difficult to measure maximal isokinetic eccentric (ECC) muscle strength in the sports field. This study aimed to investigate whether elbow isometric (ISO) flexion muscle strength or muscle thickness (MT) can be used to estimate elbow ECC flexion muscle strength. Material and methods Maximal muscle strength and muscle thickness (MT) were measured in the elbow flexor muscle group of 147 healthy adults (age: 21.3±0.8 years, height: 167.3±8.6 cm, body mass: 61.4±10.6 kg: 99 males and 48 females). Both isometric contraction (ISO) and eccentric contraction (ECC) of elbow flexion muscle strength were measured using an isokinetic dynamometer. The ultrasound measured MT at 50% of the distance from the upper arm to the lateral epicondyle. We performed the multiple regression analysis with elbow ECC flexion muscle strength as the dependent variable and gender, age, height, body mass, elbow ISO flexion muscle strength, and MT as the independent variables. Results Multiple regression analysis revealed a coefficient of determination R value of 0.89 and an adjusted R value of 0.89 (p<0.01). In addition, the independent variables elbow ISO flexor strength (p<0.01, standardized coefficient β=0.94; p<0.01, standardized coefficient β=0.89) and muscle thickness (p<0.05, standardized coefficient β=0.07) were identified as significantly associated factors. Conclusions The results suggest that it is possible to estimate elbow ECC flexion muscle strength using only elbow ISO flexion muscle strength and that ECC flexion muscle strength can be estimated more accurately by adding muscle thickness of the elbow flexor muscle group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11533147PMC
http://dx.doi.org/10.7759/cureus.70878DOI Listing

Publication Analysis

Top Keywords

muscle strength
28
flexion muscle
20
muscle
11
isokinetic eccentric
8
elbow flexor
8
flexor muscle
8
isometric contraction
8
iso flexion
8
strength muscle
8
muscle thickness
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!