In Vivo Detection of Lymph Nodes Metastasis of ESCC Using CXCR4-Targeted Tracer [Cu]Cu-NOTA-CP01.

Mol Imaging Biol

Guangdong Provincial Engineering Research Center of Molecular Imaging, The Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong Province, 519000, China.

Published: December 2024

AI Article Synopsis

  • This study explores a new method for visualizing metastatic lymph nodes (MLN) in esophageal squamous cell carcinoma (ESCC) using a CXCR4-targeted tracer called [Cu]Cu-NOTA-CP01, aiming to provide a non-invasive alternative to traditional biopsies.
  • Researchers established an intralymphatic tumor metastasis model and utilized bioluminescence imaging and PET/CT scans to assess the tracer's effectiveness and specificity for detecting MLN.
  • Results showed that the tracer successfully highlighted metastatic lymph nodes, indicating high CXCR4 expression and suggesting that this method could be a promising tool for monitoring cancer progression in patients.

Article Abstract

Purpose: Esophageal squamous cell carcinoma (ESCC) frequently exhibits skip metastasis to lymph nodes; however, non-invasive imaging techniques capable of directly visualizing metastatic lymph nodes (MLN) are still lacking. Although biopsy is the clinical standard method, it is invasive and poses risks to patient health. This study aims to detect MLN in an intralymphatic tumor metastasis model of ESCC using the CXCR4-targeted tracer [Cu]Cu-NOTA-CP01.

Procedures: The CXCR4 expression in ESCC cell lines was assessed using Western blot and immunofluorescence. An intralymphatic tumor metastasis model was established and monitored using bioluminescence imaging (BLI). Small animal PET studies and biodistribution studies were performed to evaluate the specificity of [Cu]Cu-NOTA-CP01 for MLN. Histopathology evaluation was employed to check for the presence of metastatic tumor cells and to assess CXCR4 expression levels in the metastatic lymph nodes.

Results: The intralymphatic tumor metastasis model was successfully established using the EC109/Luc cell line, which exhibited high CXCR4 expression, as verified by BLI. PET/CT imaging showed that the MLN uptakes in the baseline group were significantly inhibited in the blocking group. The ratios of MLN/muscle and MLN/blood were also significantly higher in the baseline group than in the blocking group. Ex vivo PET/CT imaging of MLN corroborated the in vivo data. Biodistribution studies further supported the PET imaging studies, showing rapid clearance of the tracer from the blood and major organs, with significantly higher MLN/muscle and MLN/blood ratios in the baseline group compared to the blocking group. Histopathological staining verified positive CXCR4 expression in these lymph nodes containing metastatic tumor cells.

Conclusions: Targeting CXCR4 with [Cu]Cu-NOTA-CP01 for PET imaging of lymph nodes metastasis represents a promising approach that warrants further investigation. These findings have the potential to enhance diagnostic and therapeutic strategies for individuals with lymph nodes metastasis of ESCC.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11307-024-01960-8DOI Listing

Publication Analysis

Top Keywords

lymph nodes
24
cxcr4 expression
16
nodes metastasis
12
intralymphatic tumor
12
tumor metastasis
12
metastasis model
12
baseline group
12
blocking group
12
metastasis escc
8
escc cxcr4-targeted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!