A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature. | LitMetric

AI Article Synopsis

  • Vacuum extractors, or ventouses, are tools used during childbirth to assist with fetal delivery and are generally safe if used correctly.
  • Using the extractor in the wrong position can lead to serious complications, such as cranial vault fractures and subgaleal hematomas, which can result in perinatal death.
  • Thorough postmortem examinations are crucial for understanding the causes of death in these cases, as they can reveal improper instrument use and help reconstruct the events of the delivery.

Article Abstract

In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PAF.0000000000000996DOI Listing

Publication Analysis

Top Keywords

cranial vault
16
vault fracture
12
vacuum extractor
12
death cranial
8
obstetric vacuum
8
perinatal death
8
postmortem examination
8
cranial
5
rare case
4
case neonatal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!