Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches. Moreover, misalignment tolerance due to IMD movements (respiratory and patient ambulatory reasons) relative to the ETAP remains a challenge. This paper presents an energy-efficient method to localize a mm-sized IMD through the dynamic selection of a sub-array within the ETAP. It is fully adaptive to the heterogeneity of the media and requires no a priori knowledge of the IMD. To improve the tolerance to IMD movements, tracking is implemented by adding and subtracting elements on the sub-array such that the sub-array electrically follows the IMD movement. Furthermore, it is shown that a minimum sampling frequency of 10X the US frequency can improve the tolerance to random noise. K-wave simulations in MATLAB are performed in different heterogenous, scattering biological media to prove the efficacy of the proposed method over standard BF methods. Measurement results in heterogenous scattering media consisting of a 3D-printed human ribs phantom and a partially blocking multipath cancellous bone phantom show an energy efficiency improvement of 10.53X and 14.4X compared to the delay-and-sum beamforming method and the unfocused transmission employing all the elements of the ETAP, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBCAS.2024.3487782 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!