A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dynamic sub-array selection-based energy-efficient localization and tracking method to power implanted medical devices in scattering heterogenous media employing ultrasound. | LitMetric

Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches. Moreover, misalignment tolerance due to IMD movements (respiratory and patient ambulatory reasons) relative to the ETAP remains a challenge. This paper presents an energy-efficient method to localize a mm-sized IMD through the dynamic selection of a sub-array within the ETAP. It is fully adaptive to the heterogeneity of the media and requires no a priori knowledge of the IMD. To improve the tolerance to IMD movements, tracking is implemented by adding and subtracting elements on the sub-array such that the sub-array electrically follows the IMD movement. Furthermore, it is shown that a minimum sampling frequency of 10X the US frequency can improve the tolerance to random noise. K-wave simulations in MATLAB are performed in different heterogenous, scattering biological media to prove the efficacy of the proposed method over standard BF methods. Measurement results in heterogenous scattering media consisting of a 3D-printed human ribs phantom and a partially blocking multipath cancellous bone phantom show an energy efficiency improvement of 10.53X and 14.4X compared to the delay-and-sum beamforming method and the unfocused transmission employing all the elements of the ETAP, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBCAS.2024.3487782DOI Listing

Publication Analysis

Top Keywords

medical devices
8
mm-sized imd
8
tolerance imd
8
imd movements
8
improve tolerance
8
heterogenous scattering
8
imd
7
etap
5
dynamic sub-array
4
sub-array selection-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!