A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Self-Reporting Multiple Microscopic Stresses Through Tunable Microcapsule Arrays. | LitMetric

Self-Reporting Multiple Microscopic Stresses Through Tunable Microcapsule Arrays.

Adv Mater

Laboratory for Soft Materials and Interfaces, Department of Materials, ETH Zürich, Vladimir-Prelog-Weg 5, Zürich, 8093, Switzerland.

Published: November 2024

AI Article Synopsis

  • Self-reporting materials enable real-time monitoring of stress and damage by triggering optical responses, like dye release, under critical stress.
  • A novel assembly strategy using microfluidic synthesis creates microcapsules that release dye at specific force levels, which are combined into organized chains for improved stress detection.
  • Experiments demonstrate that these structured materials can accurately identify and record local stresses based on emitted fluorescence, making the technique applicable to various materials through thin coatings.

Article Abstract

Self-reporting materials have emerged as a promising tool for real-time monitoring of stress and damage in structural materials. When critical stress is applied to these materials, an optical response is triggered - for example by dye release, or molecular cleavage. A key challenge is to extend these systems to respond to multiple different stress levels. To achieve this, a novel microcapsule-based assembly strategy is presented. Microfluidic synthesis is used to create microcapsules that release dye at a precise level of applied force. Subsequently, capillary assembly is used to combine microcapsules with different stress-responsiveness and different fluorescent dyes into chains, which are uniformly patterned into regular arrays, and embed these into the self-reporting materials. Through indentation experiments, it is shown that these materials can distinguish and record spatially resolved local stresses based on the fluorescence emitted upon microcapsule rupture. Crucially, the technique's accuracy is significantly improved when microcapsules are spatially organized within the material. This versatile technique can be applied to a range of different materials, via the use of thin coatings containing the regularly patterned microcapsule chains.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adma.202410945DOI Listing

Publication Analysis

Top Keywords

self-reporting materials
8
materials
6
self-reporting multiple
4
multiple microscopic
4
microscopic stresses
4
stresses tunable
4
tunable microcapsule
4
microcapsule arrays
4
arrays self-reporting
4
materials emerged
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!