Background And Objectives: The management of complex upper limb arthroplasty has received national guidelines supporting the use of a regional network. An upper limb network was established for both elbow and shoulder arthroplasty. This study evaluates the impact of establishing this network over a 5-year period.

Methods: Data were collected from network meetings from June 2017 to December 2022. Hospital-level National Joint Registry data were obtained for analysis of case volume.

Results: A total of 243 cases were discussed. Network discussion changed the management plan in 53% of cases. Only 8% of cases required transfer to the tertiary center. The proportional caseload at either hub or spoke hospitals did not change after creation of the network.

Discussion: Regional network discussion aids decision-making for complex cases, with further management options realized in over half of the cases presented. The discussion allowed every patient to gain the advantage of regional expertise while being managed conveniently at their local hospital.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11528594PMC
http://dx.doi.org/10.1177/24715492241258623DOI Listing

Publication Analysis

Top Keywords

upper limb
16
supporting regional
8
limb arthroplasty
8
impact establishing
8
regional network
8
network discussion
8
network
7
cases
5
upper
4
regional upper
4

Similar Publications

Introduction: The purpose of this study was to review rates of infection after civilian ballistic fractures and assess the effect of early antibiotic administration (EAA) on infection rates.

Methods: This was a retrospective cohort study done at an urban Level 1 Trauma Center. Patients ages 16 years and older with ballistic orthopaedic extremity injuries between May 2018 and December 2020 were enrolled.

View Article and Find Full Text PDF

Case: A 60-year-old right-hand-dominant woman experienced progressive enlargement of a mass over the index distal interphalangeal (DIP) joint over 5 years, leading to joint destruction and swan neck deformity. Radiography showed arthritis, erosion, and calcific deposition. Surgical intervention included mass excision, synovectomy, and DIP joint arthrodesis.

View Article and Find Full Text PDF

Conjugate Gradient (CG) methods are widely used for solving large-scale nonlinear systems of equations arising in various real-life applications due to their efficiency in employing vector operations. However, the global convergence analysis of CG methods remains a significant challenge. In response, this study proposes scaled versions of CG parameters based on the renowned Barzilai-Borwein approach for solving convex-constrained monotone nonlinear equations.

View Article and Find Full Text PDF

Background: Assessing various types of dysfunction in cerebral palsy is a key factor in the treatment and rehabilitation of patients. The objective of this study was to use meta-analysis and systematic review to identify the specific white matter lesions and DTI metrics strongly associated with various types of dysfunction in cerebral palsy.

Methods: We conducted a literature search of PubMed, Embase, Cochrane Library and Web of Science databases to identify trials published that had evaluated the correlation between DTI metrics in sensorimotor pathways and function scores in cerebral palsy.

View Article and Find Full Text PDF

Evaluating the performance of a new ergonomic laparoscopic needle holder for intracorporeal suturing.

PLoS One

January 2025

Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.

In laparoscopy, the absence of ergonomics in the instruments affects the performance and efficiency of the surgeon, increasing the likelihood of developing musculoskeletal injuries. This article presents the development of a laparoscopic needle holder with an ergonomic handle and the experience in its use with surgeons in the intracorporeal suturing task. The handle of the laparoscopic needle holder consists of a semi-spherical piece that easily adapts to the palm of the surgeon's hand and improves the posture and ergonomics of the wrist, allowing the direct transmission of rotational movements around the longitudinal axis of the instrument towards the tip.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!