Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Application time and viscosity are factors that can significantly affect the properties of bone cement and implant fixation. The aim of this study was to investigate the influence of different application times of 2 different cements on mechanical parameters, cement interdigitation, and cement distribution.
Methods: P.F.C. Sigma tibial trays were cemented with high-viscous Palacos R and medium- to low-viscous Simplex P in an open-cell model. The application was performed at different times within the manufacturer's specifications. Cement interdigitation and micromotion were measured with computed tomography scan using a novel method.
Results: Significant differences of insertion forces were found at all times of cement application. Cement penetration decreased with increasing pressure and viscosity. No significant differences were shown for micromotion between Palacos R and Simplex P except for an increase for Simplex P from 3 to 7 minutes at the bone-cement interface. Simplex P appeared to trap air at the implant-cement interface at 3 minutes and increased at 7 minutes.
Conclusions: Cement distribution and intrusion of Palacos R and Simplex P decreased with time. Simplex P trapped air at the implant-cement interface, decreasing the amount of contact at the implant-cement interface, which is worrisome for long-term implant fixation. Given the significant changes in cement properties after mixing, it is necessary for surgeons to understand the viscosity and timing of cement application to achieve optimal cement penetration and surface contact area to potentially decrease implant loosening. High-viscous Palacos R should be applicated immediately with doughing time and medium-viscous Simplex P for about 4 minutes considering a threshold of minimum pressure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11531636 | PMC |
http://dx.doi.org/10.1016/j.artd.2024.101476 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!