A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The use of gold and magnetite-gold composite nanoparticles for the enhanced detection of Salmonella LT2 cells under photoacoustic flow cytometry. | LitMetric

The use of gold and magnetite-gold composite nanoparticles for the enhanced detection of Salmonella LT2 cells under photoacoustic flow cytometry.

J Colloid Interface Sci

Department of Biomedical Engineering, Duquesne University, 600 Forbes Avenue Pittsburgh, Pennsylvania 15282, USA. Electronic address:

Published: February 2025

Photoacoustic flow cytometry (PAFC) is an emerging technology that has generated significant interest in several research fields, particularly in bacteremia. The application of functionalised nanoparticles like gold and iron oxide-gold complex (FeO-Au) has been realised to enhance the photoacoustic (PA) detection of bacteria cells under PAFC systems. Inclusively, the bacteria cell concentrations are statistically quantified through the number of time-signal detection counts. This study uses a similar technique by using gold (Au) and magnetite-gold complex (FeO-Au) nanoparticles in the PAFC system to improve the detection of Salmonella LT2 (SLT2) cells under 532 nm laser irradiation, resulting in over a 200 % increase. However, this study's contribution comes from the post-processing and analysis of PA time signals after exposing various concentrations of SLT2 cells. Upon fast Fourier transform (FFT) analysis of time signals, a distinct peak frequency at 2.75 MHz was significantly attributed to SLT2 as its likely acoustic frequency fingerprint, even at its lowest concentrations (10 CFU/ml). Furthermore, an electromagnetic wave simulation (optical scattering and heat transfer in fluids) was employed to distinguish the PA and Photothermal contributions of the nanoparticles in the system. The resulting data consolidates the continuous wave transform (CWT) of the time signal, where 22.5 - 30 µs was strongly affiliated with PA, and 32-40 µs was that of the photo-thermal-acoustic effect-indicating that both signals can be used to detect and potentially confirm the eradication of SLT2 cells. Overall, magnetised FeO-Au nanoparticles yielded more efficiency through its reproducible PA time signals with 0.84 standard deviations, and its 2.75 MHz frequency peak area matches most accurately with the SLT2 cell concentration by 97.3 %.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcis.2024.10.142DOI Listing

Publication Analysis

Top Keywords

slt2 cells
12
time signals
12
gold magnetite-gold
8
detection salmonella
8
salmonella lt2
8
photoacoustic flow
8
flow cytometry
8
complex feo-au
8
feo-au nanoparticles
8
analysis time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!