Unveiling Osteoporosis Through Radiomics Analysis of Hip CT Imaging.

Acad Radiol

Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, No. 34, Zhongshanbeilu, Quanzhou, 362000, China (K.F., X.L., Z.D.). Electronic address:

Published: October 2023

AI Article Synopsis

  • This study investigates the effectiveness of using radiomics analysis of hip CT scans to detect osteoporosis in patients, comparing the results to traditional clinical information.
  • The researchers extracted a range of features from CT images and applied various machine learning models, ultimately identifying 16 key features that improved osteoporosis detection accuracy.
  • The final predictive model, XGBoost, demonstrated high performance with an accuracy of 0.882 and an AUC of 0.886, indicating its potential for clinical application in osteoporosis diagnosis.

Article Abstract

Rationale And Objectives: This study aims to investigate the use of radiomics analysis of hip CT imaging to unveil osteoporosis.

Materials And Methods: The researchers analyzed hip CT scans from a cohort of patients, including both osteoporotic and healthy individuals. Radiomics technique are employed to extract a comprehensive array of features from these images, encompassing texture, shape, and intensity alterations. Radiomics analysis using the 10 most commonly used machine learning models was employed to identify screened radiomics features for the detection of osteoporosis in patients. In addition to radiomics features, the basic information of patients is also utilized as training data for these machine learning models to accurately identify the presence of osteoporosis. A comparison would be made between the efficiency of recognizing radiomics features and the efficiency of recognizing patient basic information. The machine learning model that achieves the highest performance would be chosen to integrate patient basic information and radiomics features for the development of clinical nomograms.

Result: After a thorough screening process, 16 radiomics features were selected as input parameters for the machine learning model. In the test group, the highest accuracy achieved using radiomics features was 0.849, with an area under the curve (AUC) of 0.919. Evaluation of clinical features identified age and gender as closely associated with osteoporosis. Among these features, the KNN model exhibited the highest accuracy of 0.731 and an AUC of 0.658 in the test group. Comparing the performance of radiomics and clinical features, radiomics features demonstrated superior AUC values in the machine learning models. Ultimately, the XGBoost model, utilizing both radiomics and clinical features, was selected as the final Nomogram prediction model. In the test group, this model achieved an accuracy of 0.882 and an AUC of 0.886 in screening for osteoporosis.

Conclusion: Radiomics features derived from hip CT scans exhibit strong screening capabilities for osteoporosis. Furthermore, when combined with easily obtainable clinical features like patient age and gender, an effective screening efficacy for osteoporosis can be achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2023.10.009DOI Listing

Publication Analysis

Top Keywords

radiomics features
32
machine learning
20
clinical features
16
radiomics
14
features
14
radiomics analysis
12
learning models
12
test group
12
analysis hip
8
hip imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!