A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of inorganic cations in dry milk samples deposited on a microdialysis probe by capillary electrophoresis. | LitMetric

Determination of inorganic cations in dry milk samples deposited on a microdialysis probe by capillary electrophoresis.

Food Chem

Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czechia. Electronic address:

Published: February 2025

A tubular microdialysis probe is made from polysulfone hollow fibre for human haemodialysis, which has an inner diameter of 200 μm and a thickness of 20 μm. Milk is deposited to the outer surface of the hollow fibre and allowed to dry to form a dry sample. The tubular probe is then connected to the syringe pump and microdialysis of the dry sample into 0.5 mol/L HCl as acceptor is performed. 2.5 μL of microdialysate is obtained and analyzed for inorganic cations by capillary electrophoresis with contactless conductivity detection. Baseline separation of NH, K, Ca, Na, Mg, Li is achieved in 5.5 mol/L acetic acid as background electrolyte using a fused silica capillary with inner diameter of 25 μm and length of 31.5 cm. The reproducibility of dry sample microdialysis including CE analysis for peak area ranges from 2.4 to 3.9 % after normalization to Li as internal standard.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2024.141789DOI Listing

Publication Analysis

Top Keywords

dry sample
12
inorganic cations
8
microdialysis probe
8
capillary electrophoresis
8
hollow fibre
8
inner diameter
8
dry
5
determination inorganic
4
cations dry
4
dry milk
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!