Background: Glenoid loosening is an issue in anatomic total shoulder arthroplasty (a-TSA). This has been attributed to abnormal glenoid anatomy, common among these patients. Different alternatives have been proposed to tackle glenoid bone loss and restore joint alignment with augmented glenoid implants being increasingly used to deal with this problem. This systematic review aims to evaluate the clinical and radiological outcomes of patients undergoing augmented glenoid a-TSAs. Our hypothesis was that augmented glenoid components will lead to good patient outcomes with a low incidence of complications and revision procedures.

Methods: MEDLINE, EMBASE, CENTRAL and CINHAL were searched from inception to February 2022 for information pertaining to outcomes of patients undergoing a-TSA with augmented glenoid implants.

Results: Eighteen studies reported on outcomes of 814 a-TSA (800 participants) with a mean follow-up of 3.7 years. Most studies (67%) were Type IV level of evidence. Almost 70% of participants underwent an a-TSA secondary to primary glenohumeral osteoarthritis. Most glenoids were type B2 (73%). Augmented glenoids material was mostly all-polyethylene (81%) with full wedge (45%) and stepped components (38%) designs being the most common. Most studies reported good clinical outcomes. 17 patients (4%) underwent a revision surgery.

Conclusions: Our review found that patients undergoing a-TSA with augmented glenoid components report good outcomes at short-to-mid-term follow-up. Further research is warranted to determine if such outcomes remain similar in long term.

Level Of Evidence: Level III, Systematic Review of Therapeutic Studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11523180PMC
http://dx.doi.org/10.1177/17585732231192991DOI Listing

Publication Analysis

Top Keywords

augmented glenoid
24
outcomes patients
16
patients undergoing
16
glenoid components
12
systematic review
12
glenoid
9
outcomes
8
total shoulder
8
shoulder arthroplasty
8
undergoing a-tsa
8

Similar Publications

Background: Avoiding inclination of the glenoid baseplate in reverse shoulder arthroplasty often requires considerable glenoid reaming. It is proposed that the use of a metal wedged baseplate in all patients can achieve neutral inclination with reduced glenoid reaming.

Materials And Methods: A prospective clinical single-centre study with minimum two-year follow-up was carried out.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to measure the biomechanical stability of two fixation methods (suture button and suture tape cerclage) for anterior glenoid bone grafts, comparing hand tensioning to device tensioning.
  • - Researchers tested artificial bone blocks and recorded how much displacement occurred under various forces while using a cyclic loading protocol.
  • - Results showed that device tensioning provided significantly better stability than hand tensioning for both methods, particularly at forces over 100 N, with suture buttons performing better than suture tape at higher loads.
View Article and Find Full Text PDF

Background: Shoulder stabilization surgery has evolved over time, and bony augmentation procedures on the glenoid side are being performed more often. The Latarjet procedure modifies subscapularis anatomy because the conjoined tendon divides the subscapularis muscle fibers through a split/takedown, which has structural and functional implications. Arthroscopic anatomic glenoid reconstruction (AAGR) re-creates anatomy.

View Article and Find Full Text PDF

Introduction: Recurrent shoulder dislocations often cause attrition of the labrum and progressive loss of the anterior bony contour of the glenoid. Treatment options for this pathology involve either soft tissue repair or bony augmentation procedure. The optimal management for patients with shoulder instability with subcritical bone loss remains unknown and current clinical practice is highly varied.

View Article and Find Full Text PDF

Background: Glenoid loosening is an issue in anatomic total shoulder arthroplasty (a-TSA). This has been attributed to abnormal glenoid anatomy, common among these patients. Different alternatives have been proposed to tackle glenoid bone loss and restore joint alignment with augmented glenoid implants being increasingly used to deal with this problem.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!