Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Constructing an easily repairable hydrophobic layer on the hydrogel surface that confers resistance to liquid interference remains a great challenge for hydrogel strain sensors. In this paper, superhydrophobic hydrogel sensors were prepared by driving hydrophobic organically modified silica (o-SiO) nanoparticles to the surface of polyacrylamide/sodium alginate (PAM/SA) double network hydrogels by a weak ultrasonic field in o-SiO/cyclohexane dispersion. The hydroxyl groups present on the surface of o-SiO are able to form hydrogen bonds with hydrogels, which in turn form a strong surface hydrophobic layer on its surface. The sensor exhibits superhydrophobic properties for different types of liquids, such as acids, salt solutions, etc., even in the stretched state. The broken o-SiO layers can be repaired by immersing in the o-SiO/cyclohexane dispersion. The SA significantly improved the mechanical properties as well as the strain response sensitivity of the hydrogels. The hydrogel sensor is characterized by low hysteresis to strain, wide detection range (0-894 %), low detection limit (1 %), high sensitivity (GF = 4.8), and good cyclic stability. The superhydrophobic surface allows the sensor to exhibit excellent anti-liquid interference. Salt solution droplets, prolonged contact with salt solution, and even short-term water immersion will not affect the sensor's response to strain. Moreover, repairing the broken hydrophobic layer enables the sensor to restore its resistance to liquid interference. The prepared hydrogel can be used for human motion monitoring in complex scenarios, including exercise sweating, rain, and short-time exposure to water.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijbiomac.2024.136251 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!