Novel Bragg peak characterization method using proton flux measurements on plastic scintillators.

Phys Med Biol

Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Rua Larga, 3004-516 Coimbra, Portugal.

Published: November 2024

. Bragg peak measurements play a key role in the beam quality assurance in proton therapy. Used as base data for the treatment planning softwares, the accuracy of the data is crucial when defining the range of the protons in the patient.. In this paper a protocol to reconstruct a Pristine Bragg Peak exploring the direct correlation between the particle flux and the dose deposited by particles is presented. Proton flux measurements at the HollandPTC and FLUKA Monte Carlo simulations are used for this purpose. This new protocol is applicable to plastic scintillator detectors developed for Quality Assurance applications. In order to obtain the Bragg curve using a plastic fiber detector, a PMMA phantom with a decoupled and moveable stepper was designed. The step phantom allows to change the depth of material in front of the fiber detector during irradiations. The Pristine Bragg Peak reconstruction protocol uses the measured flux of particles at each position and multiplies it by the average dose obtained from the Monte Carlo simulation at each position.. The results show that with this protocol it is possible to reconstruct the Bragg Peak with an accuracy of about 470m, which is in accordance with the tolerances set by the AAPM.. It has the advantage to be able to overcome the quenching problem of scintillators in the high ionization density region of the Bragg peak.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad8da0DOI Listing

Publication Analysis

Top Keywords

bragg peak
24
proton flux
8
flux measurements
8
quality assurance
8
protocol reconstruct
8
pristine bragg
8
monte carlo
8
fiber detector
8
peak
6
bragg
6

Similar Publications

Proton dose deposition in heterogeneous media: A TOPAS Monte Carlo simulation study.

Appl Radiat Isot

January 2025

Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, China. Electronic address:

This study investigated the influence of tissue electron density on proton beam dose distribution using TOPAS Monte Carlo simulation. Heterogeneous tissue models composed of 14 materials were constructed to simulate the dose deposition process of a 169.23 MeV proton beam.

View Article and Find Full Text PDF

The effects of mechanical vibrations on control system stability could be significant in control systems designed on the assumption of rigid-body dynamics, such as launch vehicles. Vibrational loads can also cause damage to launch vehicles due to fatigue or excitation of structural resonances. This paper investigates a method to control structural vibrations in real time using a finite number of strain measurements from a fiber Bragg grating (FBG) sensor array.

View Article and Find Full Text PDF

Adhesive joining has the severe limitation that damages/defects developed in the bondline are difficult to assess. Conventional non-destructive examination (NDE) techniques are adequate to reveal disbonding defects in fabrication and delamination near the end of service life but are not helpful in detecting and monitoring in-service degradation of the joint. Several techniques suitable for long-term joint integrity monitoring are proposed.

View Article and Find Full Text PDF

Background And Purpose: Radiotherapy induces tumor cell killing by generating DNA double strand breaks (DSBs). The effectiveness of radiotherapy is significantly influenced by the repair of DSBs, which counteracts this lethal effect. Current investigations are focused on determining whether non-homologous end joining (NHEJ) or homologous recombination is the predominant repair pathway following proton and photon radiation.

View Article and Find Full Text PDF

A wavelength demodulation method for ultra-short fiber Bragg grating (US-FBG) sensors based on an arrayed waveguide grating (AWG) and a convex optimization algorithm is proposed and demonstrated. Instead of measuring the output power ratio of the two adjacent AWG channels as previously done, in this work the wavelength demodulation is realized by reconstructing the US-FBG spectrum. The principle of spectral reconstruction involves using an AWG to sample the spectral information of US-FBG and constructing underdetermined matrix equations with the obtained prior information on transmission responses and the detected output power from multiple AWG channels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!