A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a high-performance optical sensor for sensitive detection of cobalt ions in pharmaceutical, food, biological, and environmental samples. | LitMetric

A re-generable optical chemical sensing film was created using a modified chitosan film that incorporates immobilized 4-(thiazol-2-yldiazenyl) benzene-1,3-diol (TDBD) for the detection of Co in acidic aqueous solutions. Upon exposure to Co, the film's color shifted from yellowish green to red by forming a complex between Co and TDBD. The sensor's complex was measured at 574 nm, a wavelength where the sensing membrane exhibited minimal background interference. The film exhibited its highest responsiveness to cobalt ions at pH 5.0. Two sample volumes were analysed: 2.5 mL with a Co concentration range of 8.0-140 ng/mL, and 250 mL with a concentration range of 2.4-15.2 ng/mL. Both sample sizes produced linear calibration curves, with detection limits of 2.5 and 0.7 ng/mL, respectively. The relative standard deviation was 1.35 % for six separate films in a 100 ng/mL Co solution, and 0.87 % for six individual films in a 10 ng/mL solution using 2.5 and 250 ng/mL, respectively. The sensing films demonstrated good stability over 30 days and were successfully used to determine Co in pharmaceutical, food, environmental, and biological samples, yielding satisfactory results compared to the ICP-AES method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2024.125343DOI Listing

Publication Analysis

Top Keywords

cobalt ions
8
pharmaceutical food
8
concentration range
8
development high-performance
4
high-performance optical
4
optical sensor
4
sensor sensitive
4
sensitive detection
4
detection cobalt
4
ions pharmaceutical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!