Collecting clean-caught voided urine samples is minimally invasive, but contamination occurs when urine passes through the nonsterile urethra and external genitalia. Discarding the initial urine stream may reduce these contaminants. This study hypothesized that using a midstream urine collection device would decrease bacterial and cellular contamination as compared with cleanly caught voided urine. This descriptive cross-sectional study collected urine from dogs using standard clean-caught (SCC), midstream collection device (MCD), and cystocentesis (CYS) techniques. Urinalysis and aerobic urine culture characteristics were recorded with each characteristic's prevalence described using percentages and 95% confidence intervals for each mode of collection. Positive urine culture prevalence did not differ between SCC and MCD (adjusted P value = .099); however, CYS had a lower prevalence compared with SCC and MCD (adjusted P values of <.001 [CYS versus SCC] and 0.009 [CYS versus MCD]). For other variables, there was no difference in prevalence when comparing SCC with MCD. There was no identified advantage to collecting urine using an MCD as compared with the SCC technique. Either option is a suitable alternative when CYS is not practical; however, clinicians need to interpret results cautiously because bacterial contamination is more common as compared with CYS.

Download full-text PDF

Source
http://dx.doi.org/10.5326/JAAHA-MS-7415DOI Listing

Publication Analysis

Top Keywords

collection device
12
urine
9
midstream collection
8
voided urine
8
urine culture
8
scc mcd
8
mcd adjusted
8
urine contamination
4
prevalence
4
contamination prevalence
4

Similar Publications

To evaluate the accuracy of home self-monitoring portable blood glucose meters, we analyzed the current problems of patients using portable blood glucose meters and put forward reasonable suggestions. A self-designed questionnaire was used to survey 142 patients and 132 healthcare professionals. The questionnaire consisted of 16 items with an overall score ranging from 1 to 13 (with a higher score indicating better experience).

View Article and Find Full Text PDF

Background: This study investigates the therapeutic efficacy of dynamic neuromuscular stabilization (DNS) technology paired with Kinesio Taping in patients with persistent nonspecific low back pain, as well as the effect on neuromuscular function and pain self-efficacy.

Methods: A randomized controlled clinical study was conducted to collect clinical data on DNS combined with KT for the treatment of chronic nonspecific low back pain from November 2023 to April 2024. The inclusion criteria were patients with chronic nonspecific lower back pain, aged between 18 and 30 years old, and without serious underlying medical conditions, such as cardiac disease, hypertension, and diabetes.

View Article and Find Full Text PDF

Glucocorticosteroids remain the most common pharmaceutical approach for the treatment of equine asthma but can be associated with significant side effects, including respiratory microbiome alterations. The goal of the study was to assess the impact of 2% lidocaine nebulization, a projected alternative treatment of equine asthma, on the healthy equine respiratory microbiota. A prospective, randomized, controlled, blinded, 2-way crossover study was performed, to assess the effect of 1 mg/kg 2% lidocaine (7 treatments over 4 days) on the equine respiratory microbiota compared to control horses (saline and no treatment).

View Article and Find Full Text PDF

Purpose: Preoperative virtual planning and osteosynthesis with patient-specific implants (PSIs) have become a quotidian approach to many maxillofacial elective surgery setups. When a process is well-organized, a similar approach can be harnessed to serve the needs of exact primary reconstructions, especially in midfacial trauma cases. PSI osteosynthesis of the mandible is, however, more challenging because a mirror technique of the facial sides is often unreliable due to inherent lack of symmetry, and movement of the mandible increases the risk of loosening of the osteosynthesis.

View Article and Find Full Text PDF

Background: Fixation of distal femoral fractures remains a challenge, and nonunions are common with standard constructs. Far cortical locking (FCL) constructs have been purported to lead to improved fracture-healing as compared with that achieved with traditional locking bridge plates. We sought to test this hypothesis in a comparative effectiveness clinical trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!