A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the Safety and Tolerability of Lumify Eye Illuminations Cosmetic Products. | LitMetric

Purpose: Cosmetic products applied to the periocular area can cause skin sensitivity reactions, and manufacturers routinely test the safety and tolerability of products in development. This research was sponsored by Bausch + Lomb to evaluate three Lumify Eye Illuminations products: a lash and brow serum, a hydra-gel eye cream, and a micellar water eye makeup remover.

Methods: A cumulative irritation test (CIT) study and a repeated insult patch test (RIPT) study enrolled adult males or females with no known sensitivities to cosmetic products. Three clinical safety studies enrolled adult females with self-reported characteristics targeted by each product, which was applied in a manner consistent with expected use for 8 or 12 weeks.

Results: In CIT (n=34) and RIPT (n=201) studies, faint/minimal erythema reactions were observed in 0% to 2.9% of participants; there were no moderate or severe reactions. No safety signals were observed in participants who completed clinical safety studies for lash and brow serum (n=66 enrolled, n=55 completed [83%]), eye cream (n=61 enrolled, n=52 completed [85%]), or eye makeup remover (n=80 enrolled, n=68 completed [85%]). No clinically relevant changes in visual acuity or ophthalmologic slit-lamp examination findings were noted. No participants reported ocular sensations of burning/stinging, foreign-body sensation, or soreness. At the final clinical safety study assessment, mild cutaneous erythema (as graded by the investigator) was reported for one participant (eye cream study); no other prespecified signs of cutaneous irritation (eg, edema, dryness) were observed. A treatment-related adverse event that led to study discontinuation was experienced by one participant in the eye makeup remover study (bilateral periorbital swelling).

Conclusion: Findings from rigorously conducted irritation testing and clinical safety studies indicated that these products were safe and well tolerated. Increased availability of data regarding ocular and cutaneous safety of cosmetic products can inform consumer decision-making and eye care provider recommendations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11523977PMC
http://dx.doi.org/10.2147/OPTH.S481806DOI Listing

Publication Analysis

Top Keywords

cosmetic products
16
clinical safety
16
eye cream
12
eye makeup
12
safety studies
12
eye
9
safety tolerability
8
lumify eye
8
eye illuminations
8
lash brow
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!