A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Colorimetric Fabry-Pérot Sensor with Hetero-Structured Dielectric for Humidity Monitoring. | LitMetric

Colorimetric Fabry-Pérot Sensor with Hetero-Structured Dielectric for Humidity Monitoring.

Small Methods

State Key Laboratory of Solidification Processing, MIIT Key Laboratory of Radiation Detection Materials and Devices, Center of Advanced Lubrication and Seal Materials, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an, 710072, P. R. China.

Published: October 2024

A full-color colorimetric humidity sensor with high brightness is proposed by using a hetero-structured dielectric film in a metal-insulator-metal (MIM) resonator. A humidity-responsive polymer is designed to graft on top of a metal-organic frameworks (MOFs) thin film (MOFs-Polymer) as insulator layer in the resonator. Programmable tuning of reflected color is achieved by controlling the polymer thicknesses, and finite difference time domain simulation of light-matter interactions at subwavelength scales proves the dependence of the reflected wavelength on dielectric layer thickness of the resonator. Vivid full-color changing is realized during tracking humidity process due to swelling of the stimuli-responsive polymer. Ultrafast response (≈0.75 s) is achieved for tracking trace HO from HO/methanol mixture, which is ≈10 faster than that of the pure polymer-based MIM resonator. Meanwhile, the study observes significant spectral redshift because the porous MOFs film facilitates the preconcentration of external stimulus and improves the detection sensitivity of the resonator. Further, double-channel anti-counterfeiting multiplexing imaging is devised on the MIM resonator by photomask technology. Patterned encoding for security label is achieved on the MIM resonator by engineering humidity-tunable pixels of Au/MOFs-Polymer/Au and humidity-invalid pixels of Au/MOFs/Au.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smtd.202401485DOI Listing

Publication Analysis

Top Keywords

mim resonator
16
hetero-structured dielectric
8
resonator
7
colorimetric fabry-pérot
4
fabry-pérot sensor
4
sensor hetero-structured
4
dielectric humidity
4
humidity monitoring
4
monitoring full-color
4
full-color colorimetric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!