Two methods of measuring the clearance of 99Tcm DTPA, OIH and iothalamate were compared with standard techniques of measuring the clearance rates of inulin and sodium para-aminohippurate. The best correlation was between the clearance of subcutaneously injected radiolabelled iothalamate or 99Tcm DTPA and that of inulin. 99Tcm DTPA and 131I OIH clearances measured by a two blood sample technique did not give as good a correlation with inulin and PAH clearances respectively. When measurements of GFR and tubular function were repeated on the same patients the changes measured by inulin and PAH clearances did not correlate with those measured by the two blood sample technique using 99Tcm DTPA and OIH. Our results suggest that the clearance of subcutaneously injected iothalamate or DTPA can replace inulin clearance measurements. The two blood sample technique of measuring DTPA and OIH clearance does not directly reflect inulin and PAH clearance and is insufficiently reproducible to be used to follow changes in renal function.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1259/0007-1285-59-697-35 | DOI Listing |
Aging Clin Exp Res
January 2024
Department of Nephrology, China-Japan Friendship Hospital, Beijing, China.
Aim: To evaluate the performances of the various estimated glomerular filtration rate (eGFR) equations of the Chronic Kidney Disease Epidemiology Collaboration, the Berlin Initiative Study (BIS), and the Full Age Spectrum (FAS) in older Chinese.
Methods: This study enrolled Chinese adults aged ≥ 65 years who underwent GFR measurements (via 99Tcm-DTPA renal dynamic imaging) in our hospital from 2011 to 2022. Using the measured glomerular filtration rate (mGFR) as the reference, we derived the bias, precision, accuracy, and consistency of each equation.
BMC Nephrol
May 2021
Department of Nephrology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200080, China.
Background: We aimed to investigate the accuracy of different equations in evaluating estimated glomerular filtration rate (eGFR) in a Chinese population with different BMI levels.
Methods: A total of 837 Chinese patients were enrolled, and the eGFRs were calculated by three Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, three full-age spectrum (FAS) equations and two Modification of Diet in Renal Disease (MDRD) equations. Results of measured GFR (mGFR) by the 99Tcm-diathylenetriamine pentaacetic acid (99Tcm-DTPA) renal dynamic imaging method were the reference standards.
Eur J Radiol
November 2018
Department of Radiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China.
Objective: To investigate the value of the combination of the split renal apparent diffusion coefficient (ADC) and renal parenchyma volume (RPV) by diffusion-weighted imaging (DWI) for assessment of split renal function in patients with chronic kidney disease (CKD).
Methods: Forty-eight eligible participants (36 CKD patients and 12 healthy individuals) were included in the study. All of them underwent DWI (b = 0 and 800 s/mm) examination with a 1.
Nan Fang Yi Ke Da Xue Xue Bao
June 2016
Department of Nuclear Medicine, Guangdong General Hospital//Guangdong Academy of Medical Sciences, Guangzhou 510080, China.E-mail:
Objective: To study the actual glomerular filtration rates (GFR) in patients with nonfunctioning kidneys as shown by intravenous pyelography (IVP) using single photon emission computed tomography (SPECT) dynamic renal scintigraphy and dual-plasma sample clearance method.
Methods: We retrospectively analyzed 107 patients with nonfunctioning kidneys shown by IVP who underwent renal dynamic 99Tcm-DTPA SPECT imaging. GFR was measured by Gates' methods (GFRGates') and dual-plasma sample clearance method (GFRdual-plasma).
BJU Int
June 2013
Department of Urology, Changhai Hospital, Second Military Medical University, Shanghai, China.
Objective: To identify the effects of diameter-axial-polar (DAP) scoring and other clinical variables on renal functional outcomes after partial nephrectomy (PN).
Material And Methods: A total of 59 patients with complete radiographic, clinical and follow-up information were included for analysis. Technetium Tc 99m ((99) Tc(m) )-diethylene-triamine-penta-acetic acid (DTPA) renal scintigraphy was used to determine the glomerular filtration rate (GFR) of both kidneys and each kidney individually.