Multiparametric MRI (mpMRI) and prostate-specific membrane antigen (PSMA) PET/CT are complementary imaging modalities used in the presurgical evaluation of patients with prostate cancer (PCa). The purpose of this study was to characterize clinically significant PCa (csPCa) detected and not detected by PSMA PET/CT and mpMRI, focusing on tumors detected solely by PSMA PET/CT and overlooked by mpMRI. We conducted a single-center, retrospective analysis of patients who underwent both PSMA PET/CT and mpMRI within 3 mo of each other and before radical prostatectomy. Two nuclear medicine physicians and 2 radiologists, in a masked manner, independently contoured PCa lesions on PSMA PET/CT and mpMRI, respectively. A consensus read was done with a third reader for each modality, and a majority rule was applied (2:1). After centralized imaging, a pathologic review was done by a genitourinary pathologist. We assessed agreement between imaging modalities and correlation with pathology. Logistic regression models explored associations between clinicopathologic variables and tumor detection on imaging. In total, 132 csPCa tumors from 100 patients were identified on surgical pathology. PSMA PET/CT showed higher lesion-level (87% vs. 80%) and patient-level (98% vs. 94%) sensitivity than mpMRI. Tumors detected on both imaging modalities were larger and had higher grade groups than those not detected by one or both imaging modalities. On multivariable analysis, csPCa tumors undetected by mpMRI but detected by PSMA PET/CT were smaller than those detected by both modalities. Most tumors showing aggressive pathologic features, such as the large cribriform pattern (94.7%) and the intraductal carcinoma (96%), were correctly detected by both imaging modalities. Limitations included selection bias in a surgical cohort. PSMA PET/CT tends to detect smaller csPCa not detected by mpMRI. Larger tumors on pathology with higher grade groups are more likely to be correctly detected by both imaging modalities. These findings provide insights for refining presurgical evaluation strategies in PCa.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.124.268443DOI Listing

Publication Analysis

Top Keywords

psma pet/ct
36
imaging modalities
24
detected imaging
16
pet/ct mpmri
12
detected
10
imaging
9
psma
9
pet/ct
9
prostate cancer
8
multiparametric mri
8

Similar Publications

Purpose: [Tc]Tc-HYNIC-iPSMA is a novel technetium-99m-labelled small molecule inhibitor of the prostate-specific membrane antigen (PSMA) for detecting prostate cancer (PC). The objective of this registry was to collect and evaluate [Tc]Tc-HYNIC-iPSMA patient data and images to establish the safety and tolerability, and clinical utility of this agent in imaging at different stages of PC.

Methods: Patients 18 to 80 years old with primary staging and metastatic PC were eligible.

View Article and Find Full Text PDF

Prostate cancer (PCa) outcomes vary significantly across risk groups. In early-stage localized PCa, the functional outcomes following radical prostatectomy (RP) can be severe, prompting increased interest in focal therapy, particularly High-Intensity Focused Ultrasound (HIFU). This study is to summarize the current clinical trials of HIFU on PCa.

View Article and Find Full Text PDF

Purpose: Fluorine-18 prostate-specific membrane antigen-1007 positron emission tomography/computed tomography (F-PSMA-1007 PET/CT) has been shown to be superior to multiparametric magnetic resonance imaging (MRI) for the locoregional staging of intermediate-risk and high-risk prostate tumors. This study aims to evaluate whether it is also superior in estimating tumor parameters, such as three-dimensional spatial localization and volume.

Methods: 134 participants underwent F-PSMA-1007 PET/CT and MRI prior to radical prostatectomy as part of the validating paired-cohort Next Generation Trial (NCT05141760).

View Article and Find Full Text PDF

Background And Objective: Although prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) has impacted the investigation and management of biochemical recurrence (BCR) of prostate cancer, negative scans are common at low rising prostate-specific antigen (PSA) levels. PET/CT devices with an extended axial field-of-view, such as the Siemens Biograph Vision Quadra (Quadra) scanner, have substantially higher sensitivity than conventional field-of-view scanners. Our aim was to assess whether the enhanced signal-to-noise ratios achieved on the Quadra scanner improve detection of low-volume disease and thereby increase detection of PC at low PSA levels.

View Article and Find Full Text PDF

False lymph node recurrence image in PET/CT with [68Ga]Ga-PSMA-11. Importance of the acquisition protocol.

Rev Esp Med Nucl Imagen Mol (Engl Ed)

December 2024

Servicio de Medicina Nuclear, Hospital Clínic Barcelona, Barcelona, Spain; Universitat de Barcelona, Facultad de Medicina, Barcelona, Spain; Instituto de Investigaciones Biomédicas August Pi i Sunyer (IDIBAPS), Barcelona, Spain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!