To address the under-researched risk of bisphenols (BPs) in e-cigarette liquids, comprehensive studies have been conducted to propose optimum sample preparation and analysis methods. To determine twelve BPs in refill liquids for e-cigarettes, three sample preparation methods based on distinct operational and working principles were employed. These included fabric phase sorptive extraction (FPSE), ultrasound-assisted solvent extraction of porous membrane-packed samples (UASE-PMS) and solid phase extraction (SPE) utilizing molecularly imprinted polymers (MIPs) technology. Each extraction method was combined with ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS). Key parameters of FPSE and UASE-PMS procedures were optimized. This optimization included selection of the FPSE membrane types, durations of extraction and the choice solvents. Comprehensive validation was conducted, demonstrating linearity across a range from 2 to 60 ng/mL for all BPs (BPS, BPA, BPF, BPE, BPB, BPC, BPZ, BPFL, BPBP, BPP, BPG and BPM). Determination coefficients were above 0.9913, signifying linear relationship. The limits of detection (LODs) were established below 0.90 ng/mL, while the limits of quantification (LOQs) were lower than 2.5 ng/mL. Notably, the method based on UASE-PMS was successfully applied to the analysis of refill liquids for e-cigarettes samples. A comparative analysis of the methods highlighted variances in precision, accuracy, and applicable aspects, such as adjustment of parameters, sample preparation time, cost, handling, availability and possible limitations. Three methods have been identified as suitable for analysing BPs in e-cigarette refill liquids, highlighting the necessity to examine their presence in these products.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2024.127096 | DOI Listing |
Mikrochim Acta
January 2025
College of Geography and Environmental Sciences, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua, 321004, China.
Myoglobin (Mb), an important cardiac marker, plays a crucial role in diagnosing, monitoring, and evaluating the condition of patients with cardiovascular diseases. Here, we propose a label-free photoelectrochemical (PEC) sensor for the detection of Mb through target regulated the photoactivity of AgS/FeOOH heterojunction. The AgS/FeOOH nanospindles were synthesized and served as a sensing platform for the fabrication of bio-recognized process for Mb.
View Article and Find Full Text PDFJ Coll Physicians Surg Pak
January 2025
Department of Stomatology, The Second People's Hospital of Hefei and Hefei Hospital Affiliated to Anhui Medical University, Hefei, Anhui, China.
Objective: To investigate the effects of bulk-fill, resin-based composite types (high or low viscosity) on the internal adaptation of Class V restorations.
Study Design: Experimental study. Place and Duration of the Study: Hefei Stomatological Hospital, Hefei, China, from October 2022 to December 2023.
Anal Methods
November 2017
Anhui Key Laboratory of Chemo-Biosensing, Key Laboratory of Functional Molecular Solids, Ministry of Education, College of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, PR China.
A new aptamer-based surface plasmon resonance (SPR) system has been designed to detect Hg that utilizes near-infrared (NIR)-to-NIR gold nanoparticle coated NaYF:Yb,Tm,Gd up-conversion nanoparticles (AuNPs@NaYF:Yb,Tm,Gd UCNPs) as probes. The AuNPs@NaYF:Yb,Tm,Gd UCNPs were prepared and excited by near-infrared light (980 nm) which emitted at a near-infrared wavelength (808 nm) using an inexpensive infrared continuous wave laser diode. The AuNPs@NaYF:Yb,Tm,Gd UCNPs were conjugated with Hg aptamers.
View Article and Find Full Text PDFAnal Methods
November 2017
College of Environmental and Chemical Engineering, Nanchang Hangkong University, Nanchang 330063, China.
A novel method was established using a restricted access material combined with a molecularly imprinted polymer (RAM-MIP) as the sorbent material in solid phase extraction (SPE) for clean-up of α-endosulfan, β-endosulfan, endosulfate, endosulfan-ether, endosulfan lactone, heptachlor, heptachlor--epoxide, and heptachlor--epoxide in pork and gas chromatography (GC) for determination. The RAM-MIP was prepared by precipitation polymerization by using endosulfan as the template, methacrylic acid (MAA) as the monomer, glycidyl methacrylate (GMA) as the pro-hydrophilic co-monomer, ethylene glycol dimethacrylate (EGDMA) as the crosslinker, azobisisobutyronitrile (AIBN) as the initiator, and toluene as the porogen. Ultraviolet spectroscopy (UV) and H-nuclear magnetic resonance (H-NMR) analysis verified that MAA interacted specifically with endosulfan in a ratio of 1 : 1 in the pre-polymerization solution.
View Article and Find Full Text PDFBMC Complement Med Ther
January 2025
Department of Health Information Technology, Abadan University of Medical Sciences, Abadan, Iran.
Background: Currently, there is no agreed-upon data collection tool for comprehensively structured documentation of Iranian traditional medicine (ITM) from the information management perspective. As ITM practice varies significantly from current medicine in diagnosis and treatment approaches, it is not appropriate to use data platforms or information systems developed for current medicine. Consequently, the collected data are non-comparable, reducing the verdicts' generalization.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!