Purpose: To assess the diagnostic performance and inter-observer agreement of a PREoperative sarcoma scoring based on ultrasound (PRESS-US) in differentiating uterine leiomyosarcoma (uLMS) from leiomyoma (LM).
Methods: We conducted a retrospective evaluation of patients who underwent surgery and received standardized ultrasound examinations due to the presence of uterine myoma-like masses. Histological diagnosis was used as the reference standard. The masses were analyzed using morphological uterus sonographic assessment criteria, and the diagnostic accuracy of PRESS-US was evaluated using ROC curve analysis. Kappa (κ) statistics were used to assess the inter-observer agreement between a less experienced and an expert radiologist.
Results: Among the 646 patients, 632 (97.8%) were diagnosed with LM, and 14 (2.2%) had uLMS. The malignancy rates for low-risk and high-risk patients were 0.35% and 13.48%, respectively. The optimal PRESS-US cutoff was 17.5, resulting in an AUC of 89.7% (95% CI, 0.79-1.00), with a sensitivity of 85.7% and a specificity of 87.8%. The inter-observer agreement between a less experienced and an expert radiologist was excellent (κ = 0.811, P < 0.001).
Conclusions: PRESS-US provides effective risk stratification for uLMS for radiologists with different levels of experience, with high reliability. Subgrouping high-risk patients helps in better risk stratification.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11547-024-01903-x | DOI Listing |
Insights Imaging
January 2025
Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, China.
Objectives: To investigate the image quality and diagnostic performance with ultra-low dose dual-layer detector spectral CT (DLSCT) by various reconstruction techniques for evaluation of pulmonary nodules.
Materials And Methods: Between April 2023 and December 2023, patients with suspected pulmonary nodules were prospectively enrolled and underwent regular-dose chest CT (RDCT; 120 kVp/automatic tube current) and ultra-low dose CT (ULDCT; 100 kVp/10 mAs) on a DLSCT scanner. ULDCT was reconstructed with hybrid iterative reconstruction (HIR), electron density map (EDM), and virtual monoenergetic images at 40 keV and 70 keV.
Oral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Surgery, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
Purpose: This study aimed to clarify the applicability of smartphone-based three-dimensional (3D) surface imaging for clinical use in oral and maxillofacial surgery, comparing two smartphone-based approaches to the gold standard.
Methods: Facial surface models (SMs) were generated for 30 volunteers (15 men, 15 women) using the Vectra M5 (Canfield Scientific, USA), the TrueDepth camera of the iPhone 14 Pro (Apple Inc., USA), and the iPhone 14 Pro with photogrammetry.
J Ultrasound Med
January 2025
Department of Ultrasonic Medicine, Fetal Medical Centre, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.
Introduction: Acoustic shadowing is an important benign ultrasound (US) feature for adnexal masses (AMs). To validate the diagnostic performance and interobserver agreement of the 2019 version and 2022 version of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) and ascertain whether adding acoustic shadowing to O-RADS US v2019 as a benign ultrasound feature can enhance its diagnostic efficacy among junior radiologist.
Methods: This retrospective study included consecutive women with suspected adnexal masses who underwent ultrasound examinations between September 2022 and January 2024.
Biomed Eng Lett
January 2025
Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505 South Korea.
Unlabelled: Accurate assessment of shoulder range of motion (ROM) is crucial for evaluating patient progress. Traditional manual goniometry often lacks precision and is subject to inter-observer variability, especially in measuring shoulder internal rotation (IR). This study introduces an artificial intelligence (AI)-based approach that uses clinical photography to improve the accuracy of ROM quantification.
View Article and Find Full Text PDFOrthod Craniofac Res
January 2025
Oral and Maxillofacial Pathology and Oral Medicine, Faculty of Dentistry, University of Toronto, Toronto, Ontario, Canada.
Objectives: Radiographs are routinely acquired for orthodontic evaluation, and incidental findings (IFs) may be detected early as part of this routine care. This study aimed to assess the prevalence of IFs on panoramic radiographs taken for orthodontic assessment and evaluate the ability of orthodontists to detect, interpret and recommend management for IFs.
Materials And Methods: A retrospective analysis of 1756 patients aged 7-21 with a panoramic image taken for orthodontic evaluation was performed.