  • The study evaluated the safety and effectiveness of reconstructing alveolar bone while removing implants due to advanced peri-implantitis in patients looking to replace failed implants for aesthetic or functional reasons.
  • A mix of xenograft and autogenous bone was used along with a barrier membrane to regenerate bone, with radiographic assessments conducted before and after the procedure.
  • Results showed significant improvements in alveolar ridge width and height, with a large percentage of implants maintaining health after follow-up, indicating the method is safe and effective for developing implant sites.

Article Abstract

Objective: To evaluate the safety and effectiveness of alveolar bone reconstruction simultaneous to implant removal due to peri-implantitis.

Material And Methods: Partial or fully dentulous patients subjected to implant removal due to advanced peri-implantitis (≥ 50% of bone loss) lesions and seeking to have the failed implant replaced for esthetic or functional reasons were consecutively included. Guided bone regeneration was performed by means of a mixture of xenograft and autogenous bone and a ribose cross-linked barrier membrane. Re-entry for implant placement was performed at 4-month follow-up. Overall, six radiographic variables were assessed before (T0) and after (T1) alveolar bone reconstruction at four levels in ridge width (RW) and height (RH). Peri-implant conditions were evaluated at latest follow-up. Simple and multiple binary logistic regression models were calculated using generalized estimation equations to evaluate the effect of baseline upon reconstructive outcomes.

Results: In total, 20 patients (n = 39) met the inclusion criteria. Alveolar RW and RH were augmented from T0 to T1 at all levels. All implants achieved primary stability. Only ~13% were subjected to ancillary bone regeneration simultaneous to implant placement. After a mean follow-up period after loading of ~2.2 years, ~70% implants demonstrated peri-implant health, while mucositis was diagnosed in the remaining implants.

Conclusion: The performance of alveolar bone reconstruction in residual partially contained defects simultaneous to implant removal due to peri-implantitis lesions demonstrates being safe and effective for implant site development.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jerd.13352DOI Listing

Publication Analysis

Top Keywords

alveolar bone
16
bone reconstruction
16
simultaneous implant
16
implant removal
16
reconstruction simultaneous
8
implant
8
removal advanced
8
advanced peri-implantitis
8
bone regeneration
8
implant placement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!