A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Treatment planning with high-resolution 3D dose maps in preclinical and translational synchrotron microbeam radiation therapy. | LitMetric

Background And Purpose: Microbeam Radiation Therapy (MRT) aims to deliver higher doses to the target while minimizing radiation damage to healthy tissues using synchrotron x-ray microbeams. Translational MRT research has now started, driven by promising results from preclinical studies. This study aimed to propose a first dose-outcome model by analyzing micrometric dose distributions obtained with high-resolution 3D dose calculations, accounting for the inherent physical dose distribution complexity in MRT. The feasibility of integrating penMRT, our full Monte Carlo multiscale dose calculation algorithm based on PENELOPE into translational research on veterinary patients was also investigated.

Material And Methods: Micrometric dose distributions were calculated in tumor-bearing rats and for a veterinary patient with penMRT, for conformal multi-directional MRT treatment plans. Absorbed dose maps were obtained with 0.005 × 0.005 × 1 mm voxel sizes. High-resolution dose-volume histograms were extracted and analyzed against radiobiology studies.

Results: The complexity of the MRT dose distribution was properly rendered at a micrometer scale on 3D dose maps, with well separated dose regions observed on the differential dose-volume histograms. The median survival time of glioma-bearing rats varied linearly with the volume fraction of the planning target volume that received doses higher than 50 Gy (R = 0.98). The feasibility of using penMRT for treatment planning in large volumes has been shown on a veterinary patient.

Conclusions: This study demonstrated the significant added value of penMRT for planning and prescribing MRT treatments. It also shed light on the correlation between the high-resolution 3D dose distributions and the treatment outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11519677PMC
http://dx.doi.org/10.1016/j.phro.2024.100565DOI Listing

Publication Analysis

Top Keywords

high-resolution dose
12
dose maps
12
dose distributions
12
dose
11
treatment planning
8
microbeam radiation
8
radiation therapy
8
micrometric dose
8
dose distribution
8
complexity mrt
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!