TCDDU-Net: combining transformer and convolutional dual-path decoding U-Net for retinal vessel segmentation.

Sci Rep

College of Information Engineering, Xinjiang Institute of Technology, No.1 Xuefu West Road, Aksu, 843100, Xinjiang, China.

Published: October 2024

Accurate segmentation of retinal blood vessels is crucial for enhancing diagnostic efficiency and preventing disease progression. However, the small size and complex structure of retinal blood vessels, coupled with low contrast in corresponding fundus images, pose significant challenges for this task. We propose a novel approach for retinal vessel segmentation, which combines the transformer and convolutional dual-path decoding U-Net (TCDDU-Net). We propose the selective dense connection swin transformer block, which converts the input feature map into patches, introduces MLPs to generate probabilities, and performs selective fusion at different stages. This structure forms a dense connection framework, enabling the capture of long-distance dependencies and effective fusion of features across different stages. The subsequent stage involves the design of the background decoder, which utilizes deformable convolution to learn the background information of retinal vessels by treating them as segmentation objects. This is then combined with the foreground decoder to form a dual-path decoding U-Net. Finally, the foreground segmentation results and the processed background segmentation results are fused to obtain the final retinal vessel segmentation map. To evaluate the effectiveness of our method, we performed experiments on the DRIVE, STARE, and CHASE datasets for retinal vessel segmentation. Experimental results show that the segmentation accuracies of our algorithms are 96.98, 97.40, and 97.23, and the AUC metrics are 98.68, 98.56, and 98.50, respectively.In addition, we evaluated our methods using F1 score, specificity, and sensitivity metrics. Through a comparative analysis, we found that our proposed TCDDU-Net method effectively improves retinal vessel segmentation performance and achieves impressive results on multiple datasets compared to existing methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11522399PMC
http://dx.doi.org/10.1038/s41598-024-77464-wDOI Listing

Publication Analysis

Top Keywords

retinal vessel
20
vessel segmentation
20
dual-path decoding
12
decoding u-net
12
segmentation
10
transformer convolutional
8
convolutional dual-path
8
retinal
8
retinal blood
8
blood vessels
8

Similar Publications

Does Nocturnal Blood Pressure Matter in Retinal Small Vessels? A Systematic Review and Meta-Analysis of the Literature.

Curr Hypertens Rep

January 2025

Department of Internal Medicine, Aristotle University, Hypertension, Hypertension-24h ambulatory blood pressure monitoring center, Papageorgiou Hospital, Thessaloniki, Greece.

Purpose Of The Review: Τhe association between nocturnal blood pressure (BP) and alterations in the retinal microvasculature remains understudied, with few available studies to provide conflicting results. Therefore, we conducted a systematic review and meta-analysis to determine whether an association exists between retinal microvascular alterations and nocturnal BP patterns, determined by 24h ambulatory BP measurement.

Recent Findings: Our search concluded to 1002 patients (6 studies).

View Article and Find Full Text PDF

Purpose: To study choroidal thickness (CT) and luminal areas of choroidal vessels in the setting of fovea-off rhegmatogenous retinal detachment (RRD).

Methods: Twenty-seven eyes with RRD were prospectively studied before and after pars plana vitrectomy and SF6 tamponade, using swept-source optical coherence tomography (SS-OCT). CT was measured pre- and postoperatively both subfoveally and in attached macular areas.

View Article and Find Full Text PDF

Background: This study evaluates retinal oxygen saturation and vessel density within the macula and correlates these measures in controls and subjects with type 2 diabetes (DM) with (DMR) and without (DMnR) retinopathy. Changes in retinal oxygen saturation have not been evaluated regionally in diabetic patients.

Methods: Data from seventy subjects (28 controls, 26 DMnR, and 16 DMR were analyzed.

View Article and Find Full Text PDF

COph100: A comprehensive fundus image registration dataset from infants constituting the "RIDIRP" database.

Sci Data

January 2025

Research Institute of Trustworthy Autonomous Systems and Department of Computer Science and Engineering, Southern University of Science and Technology, Shenzhen, China.

Retinal image registration is vital for diagnostic therapeutic applications within the field of ophthalmology. Existing public datasets, focusing on adult retinal pathologies with high-quality images, have limited number of image pairs and neglect clinical challenges. To address this gap, we introduce COph100, a novel and challenging dataset known as the Comprehensive Ophthalmology Retinal Image Registration dataset for infants with a wide range of image quality issues constituting the public "RIDIRP" database.

View Article and Find Full Text PDF

Purpose: To investigate the repeatability of optical coherence tomography angiography (OCTA) parameters in participants with different severities of glaucoma.

Methods: Subjects with open-angle glaucoma were enrolled prospectively and categorised into mild (mean deviation [MD] of 24-2 visual field test ≥ -6 dB), moderate to advanced (-6 > MD ≥ -20 dB) and severe glaucoma groups (MD < -20 dB). OCTA was performed three times within a single visit to obtain superficial and deep macular vessel density (VD) and peripapillary vessel and capillary density.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!