Objective: Stress concentration and excessive wear on the opposite jaw teeth are the main problems that lead to the failure of all-ceramic crown restoration. The objectives of this study were to: (1) Synthesize the biomimetic gradient zirconia/resin composites. (2) Control the porosity and structure so that the mechanical properties of the biomimetic gradient zirconia/resin composites are close to enamel and dentin.

Methods: Biomimetic uniform zirconia scaffolds with different widths (1.6 mm, 1.8 mm, 1.9 mm, 2.0 mm, 2.2 mm) and Biomimetic gradient (1.6 mm-2.2 mm) zirconia scaffolds were designed using 3DMax and Magics, fabricated by digital light processing 3D printing, and then infiltrated into dental resin for mechanical testing, finite element simulation and cytotoxicity testing.

Results: Results show that the ceramic-polymer composites exhibit a significant enhancement in strength (1.37-fold increase) and toughness (2.08-fold increase) compared to zirconia ceramic scaffold (P < 0.05), highlighting the effectiveness of our structural design. In addition, the gradient design further improves the mechanical strength of the composites. Notably, the gradient composite crown exhibits a bending strength of 138.3 (±16.7) MPa, a toughness of 9.0 (±0.5) MJ/m³, and a compressive strength of 113.7 (±2.6) MPa, values that are comparable to those of natural enamel and dentin, and shows good biosafety.

Conclusion: Biomimetic gradient zirconia/dental resin materials were precisely fabricated through a series of studies, which is expected to further improve the clinical treatment effect. At the same time, the strategic design also provides new ideas for the performance improvement of other dental materials.

Significance: Gradient zirconia/resin composite materials with mechanical properties matching natural teeth were precisely fabricated, and are expected to significantly improve clinical treatment outcomes. Additionally, the strategic design provides new insights for enhancing the performance of other dental materials.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2024.10.010DOI Listing

Publication Analysis

Top Keywords

biomimetic gradient
12
digital light
8
gradient zirconia/resin
8
zirconia/resin composites
8
zirconia scaffolds
8
biomimetic
5
light printing
4
printing zirconia/resin
4
zirconia/resin composite
4
composite material
4

Similar Publications

Photo-Controllable Förster Resonance Energy Transfer Based on Dynamic Chiral Self-Assembly of Sequence-Defined Amphiphilic Alternating Azopeptoids.

Small

January 2025

Shanghai Key Laboratory of Advanced Polymeric Materials, Frontiers Science Center for Materiobiology and Dynamic Chemistry, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, 200237, China.

Endowing biomimetic sequence-controlled polymers with chiral functionality to construct stimuli-responsive chiral materials offers a promising approach for innovative chiroptical switch, but it remains challenging. Herein, it is reported that the self-assembly of sequence-defined chiral amphiphilic alternating azopeptoids to generate photo-responsive and ultrathin bilayer peptoidosomes with a vesicular thickness of ≈1.50 nm and a diameter of around ≈290 nm.

View Article and Find Full Text PDF

In situ swelling of low-friction, high load-bearing self-bending bilayer hydrogels inspired by articular cartilage.

Biomed Mater

January 2025

School of Advanced Manufacturing, Nanchang University - Qianhu Campus, Nanchang, Jiangxi, China, Nanchang, --- Select One ---, 330031, CHINA.

The articular cartilage is characterized by its gradient hierarchical structure, which exhibits excellent lubrication and robust load-bearing properties. However, its inherent difficulty in self-repair after damage presents numerous formidable challenges for cartilage repair. Inspired by the unique structure of articular cartilage, a biomimetic bilayer hydrogel composed of PAM (polyacrylamide) and PAM/SA (sodium alginate) is prepared using a two-step in-situ swelling method.

View Article and Find Full Text PDF

Intelligent soft robots that integrate both structural color and controllable actuation ability have attracted substantial attention for constructing biomimetic systems, biomedical devices, and soft robotics. However, simultaneously endowing single-layer cholesteric liquid crystal elastomer (CLCE) soft actuators with reversible 3D deformability and vivid structural color changes is still challenging. Herein, a multi-responsive (force, heat and light) single-layer 3D deformable soft actuator with vivid structural color-changing ability is realized through the reduced graphene oxide (RGO) deposition-induced Janus structure of the CLCE using a precisely-controlled evaporation method.

View Article and Find Full Text PDF

Deep Neural Networks for Accurate Depth Estimation with Latent Space Features.

Biomimetics (Basel)

December 2024

School of Artificial Intelligence, Tongmyong University, Busan 48520, Republic of Korea.

Depth estimation plays a pivotal role in advancing human-robot interactions, especially in indoor environments where accurate 3D scene reconstruction is essential for tasks like navigation and object handling. Monocular depth estimation, which relies on a single RGB camera, offers a more affordable solution compared to traditional methods that use stereo cameras or LiDAR. However, despite recent progress, many monocular approaches struggle with accurately defining depth boundaries, leading to less precise reconstructions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!