Statement Of Problem: As part of the growing digitization of the dental field, clinicians are looking for ways to simplify digital workflow, reduce chairside time, and provide new work patterns for future applications. Whether scanning with a multifunctional apparatus (MFA) scan body results in improved scanning is unclear.
Purpose: The purpose of this in vitro study was to compare the horizontal, vertical, and angular deviations with the MFA scan body with a commercially available scan body (SBIO).
Material And Methods: Sixteen identically printed edentulous maxillary models were used to plan two Ø3.8×11.5-mm implants in the right maxillary first molar and left maxillary central incisor locations. Two implants in each model were installed using a surgical guide. The models were scanned using an intraoral scanner with MFA and then rescanned twice, with SBIO using the intraoral scanner and a laboratory 3D scanner. The implants were digitally positioned according to the scanned MFA and SBIO locations in standard tessellation language (STL) files. These STL files were superimposed on the reference laboratory 3D scanner STL files. Linear measurements included implant apex/cervical horizontal/vertical deviations, as well as implant axis angular deviations. Normality was evaluated with the Shapiro-Wilk test. Paired samples t tests (2 sided) were used for the mean SBIO-MFA deviation difference. To compare the molar/incisor sites, paired samples Wilcoxon tests were used (α=.05 for all tests).
Results: No statistically significant differences were found between the MFA/ SBIO deviations, for each of the 10 sites × deviation combinations (P>.05). Overall, the lowest endpoint of the 95% confidence intervals among the 8 linear measurement comparisons was -0.107 mm (coronal vertical deviation, right maxillary first molar site) and -0.30 degrees between the 2 angular measurement comparisons.
Conclusions: The current in vitro study demonstrated high accuracy for the novel MFA device, similar to that of the standard SBIO scan body. Furthermore, the current study offers an alternative technique to evaluate the accuracy of implant placement by using scanning and back programming over the traditional postplacement cone beam computed tomography (CBCT) scanning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2024.09.027 | DOI Listing |
Skeletal Radiol
January 2025
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Jena, Am Klinikum 1, 07747, Jena, Germany.
Objective: This study is aimed at evaluating the distribution of metastatic bone disease (MBD), with a particular focus on the humerus, and its association with pathological fractures. Factors for contributing to the underestimation of fracture risk were assessed, including their impact on surgical management.
Materials And Methods: We retrospectively reviewed patient records of patients undergoing surgical treatment for MBD at our institution between 2005 and 2023.
J Cachexia Sarcopenia Muscle
January 2025
Department of Medical Oncology, Lille University Hospital, Lille, France.
Background: Advanced pancreatic ductal adenocarcinoma (aPDAC) is often accompanied by significant muscle mass loss, contributing to poor prognosis. SarcAPACaP, an ancillary study of the GERCOR-APACaP phase III trial, evaluated the role of adapted physical activity (APA) in aPDAC Western patients receiving first-line chemotherapy. The study aimed to assess (1) the potential impact of computed tomography (CT)-quantified muscle mass before and during treatments on health-related quality of life (HRQoL) and overall survival (OS) and (2) the role of APA in mitigating muscle mass loss.
View Article and Find Full Text PDFBMC Pediatr
January 2025
Department of Pulmonology, Tianjin Children's Hospital (Children's Hospital of Tianjin University), Machang compus, 225 Machang Road, Hexi District, Tianjin, 300074, China.
Background: Foreign body inhalation is rare in older children, often leading to underdiagnosis and delayed treatment. Most cases involve a single foreign body, but instances of multiple foreign bodies are exceedingly uncommon. This report presents a case of an elder child who inhaled two pen caps, emphasizing the need for clinical vigilance and thorough medical history collection.
View Article and Find Full Text PDFBMC Nephrol
January 2025
Department of Urology, Nara Medical University, 840 Shijo-cho, Kashihara, Nara, 634-8522, Japan.
Background: The existing criteria for living kidney donors (LKDs)in Japan are controversial. We evaluated the roles of computed tomography volumetry (CTV) and 99 m Tc-diethylenetriamine penta-acetic acid (DTPA) scintigraphy in assessing preoperative and postoperative renal function and predicting early recovery of residual renal function.
Methods: We retrospectively reviewed the medical charts of 175 consecutive LKDs who underwent donor nephrectomy (DN) at our institution between 2006 and 2022.
Indian J Thorac Cardiovasc Surg
February 2025
Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka India.
Autoimmune hemolytic anemia (AIHA) secondary to mediastinal teratoma is a very rare clinical entity. They can be primary or secondary to any infections, malignancy, etc. Yet at times, there could be a delay in the diagnosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!