A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of trueness, time, and number of images among different denture digitization protocols. | LitMetric

Purpose: To compare trueness, time, and number of images of different denture digitization protocols.

Materials And Methods: Maxillary and mandibular complete prostheses (n = 10) were fabricated and attached with four fiducial markers. Reference scans were obtained using a laboratory scanner. Test scans were obtained using three different protocols: intraoral scanner (IOS) with manufacturer's scanning pattern (MA), IOS with rolling scanning pattern (RO), and IOS- polyvinylsiloxane technique (IOS-PVS). The scan time and number of images taken were recorded for analysis. Using 3-dimensional (3D) inspection software (Geomagic control X), corresponding test scans were superimposed to the reference scan using overall best fit. For trueness analysis, the root mean square (RMS) value of the overall best-fit superimposition was calculated. One-way ANOVA followed by Games-Howell and Tukey post-hoc tests were applied to analyze trueness, scan time, and number of images. Qualitative analysis of trueness was performed using 3D color mapping.

Results: The lowest RMS value was in the mandibular RO protocol (0.10 ±0.01 mm). The highest RMS value was mandibular scans of the IOS-PVS protocol (1.46 ± 0.09 mm). The longest digitization time was recorded in the maxillary MA group (3.34 ± 0.70 min), while the shortest was in the mandibular RO protocol (2.48 ± 0.56 min). Qualitative analysis revealed that deviation in IOS-PVS protocol occurred around the border area of the prosthesis.

Conclusion: The denture digitization protocols tested significantly affected trueness, total scanning time, and number of images. Digitizing dentures using the RO protocol improved trueness and reduced scanning time and the number of images.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13967DOI Listing

Publication Analysis

Top Keywords

time number
24
number images
24
denture digitization
12
trueness time
8
images denture
8
digitization protocols
8
test scans
8
scanning pattern
8
scan time
8
qualitative analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!